Removal of the Proximity Switches of the Aft Emergency Exits


TASK 52-73-11-000-004-E
Removal of the Proximity Switches of the Aft Emergency Exits


WARNING: STOP THE OPENING PROCEDURE IF THE RED WARNING LIGHT FLASHES. IF THE RED WARNING LIGHT FLASHES, REMAINING PRESSURE CAN CAUSE THE DOOR TO OPEN SUDDENLY AND CAN:
  • KILL OR CAUSE SERIOUS INJURY TO PERSONS
  • CAUSE DAMAGE TO THE AIRCRAFT.
ZONE: 835
ZONE: 845
FIN: 6WN1 ** ON A/C NOT FOR ALL
FIN: 6WN2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
835
MID PASSENGER/CREW DOOR
845
MID PASSENGER/CREW DOOR
835, 845
FOR [6WN1] (PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE)
835CZ
FOR [6WN2] (PROX SW-HANDLE, R AFT EMER EXIT ESC SLIDE)
845CZ
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 25-23-47-000-802-A
Removal of the Door Linings of the Emergency Exit, zones 251/252
TASK 52-22-00-010-002-A
Opening of the Emergency Exit Doors from the Outside
TASK 52-22-00-860-003-A
Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder
3. Job Set-up
Subtask 52-73-11-861-061-A ** ON A/C NOT FOR ALL
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
Subtask 52-73-11-865-080-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
Subtask 52-73-11-010-069-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at applicable emergency exits 835 or 845.
   (2) Open the applicable emergency exits (Ref. AMM TASK 52-22-00-010-002).
   (3) Obey the special precautions before you start work on the emergency exits (Ref. AMM TASK 52-22-00-860-003).
Subtask 52-73-11-010-070-A ** ON A/C NOT FOR ALL
D. Removal of the Lining Panel
   (1) Remove the applicable lining panel (Ref. AMM TASK 25-23-47-000-802):
     (a) FOR [6WN1] (PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE)
     (b) FOR [6WN2] (PROX SW-HANDLE, R AFT EMER EXIT ESC SLIDE)
   (2) Remove the insulation.
4. Procedure
Subtask 52-73-11-020-062-A ** ON A/C NOT FOR ALL
A. Removal of the Proximity Switch
   (1) Disconnect the electrical connector (1) from the proximity switch (2).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Removal of the lockwire:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Remove and discard the lockwire from the nut (4).
   (4) Remove the nut (4) and the washer (3).
   (5) Remove the proximity switch (2) from its support.