1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
WRENCH - SPANNER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
241
CENTER PASSENGER COMPARTMENT
242
CENTER PASSENGER COMPARTMENT
831, 841
FOR [6WN1] (PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE)
241FW
FOR [6WN2] (PROX SW-HANDLE, R AFT EMER EXIT ESC SLIDE)
242FW
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 52-10-00-010-001-A
Opening of the Passenger/Crew Door
FOR [6WN1] (PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE)
TASK 25-23-47-000-002-A
Removal of the Upper Sidewall Panel Assy 241LW, (242LW), 241CW, (242CW) and 241FW, (242FW)
FOR [6WN2] (PROX SW-HANDLE, R AFT EMER EXIT ESC SLIDE)
TASK 25-23-47-000-002-A
Removal of the Upper Sidewall Panel Assy 241LW, (242LW), 241CW, (242CW) and 241FW, (242FW)
3. Job Set-up
Subtask 52-73-11-861-058-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 52-73-11-010-056-A ** ON A/C NOT FOR ALL
B. Get Access
WARNING: DO NOT OPEN THE PASSENGER/CREW DOOR IF THE WIND SPEED IS MORE THAN 65 KNOTS.
WARNING: STOP THE OPENING PROCEDURE IF THE RED WARNING LIGHT FLASHES. IF THE RED WARNING LIGHT FLASHES, REMAINING PRESSURE CAN CAUSE THE DOOR TO OPEN SUDDENLY AND CAN:
  • KILL OR CAUSE SERIOUS INJURY TO PERSONS
  • CAUSE DAMAGE TO THE AIRCRAFT.
   (1) Put an ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position in front of the applicable FWD passenger/crew door 831 or 841.
   (2) Open the applicable FWD passenger/crew door 831 or 841 (Ref. AMM TASK 52-10-00-010-001).
Subtask 52-73-11-865-071-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
Subtask 52-73-11-010-064-A ** ON A/C NOT FOR ALL
D. Disarming of the Escape Slide of the Emergency Exit
   (1) Disarm the escape slide of the emergency exits (10) as follows:
     (a) Open and remove the flaps (8).
NOTE: The white SLIDE ARMED indicator-light (11) comes on.
     (b) Turn the head of the latch pin (9) with a WRENCH - SPANNER a quarter turncounterclockwise to retract the latch pin (9).
NOTE: The white SLIDE ARMED indicator-light (11) goes off.
Subtask 52-73-11-010-057-A ** ON A/C NOT FOR ALL
E. Removal of the Lining Panel
   (1) Disconnect the electrical connector from the SLIDE ARMED indicator-light.
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove the lining panel:
     (a) FOR [6WN1] (PROX SW-HANDLE, L AFT EMER EXIT ESC SLIDE)
241FW (Ref. AMM TASK 25-23-47-000-002).
     (b) FOR [6WN2] (PROX SW-HANDLE, R AFT EMER EXIT ESC SLIDE)
242FW (Ref. AMM TASK 25-23-47-000-002).
   (4) Remove the insulation blanket.
   (5) Remove the air outlet (7).
4. Procedure
Subtask 52-73-11-020-057-A ** ON A/C NOT FOR ALL
A. Removal of the Proximity Switch
   (1) Disconnect the electrical connector (1) from the proximity switch (2).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove and discard the lockwire.
   (4) Remove the nut (5) and the washer (4).
   (5) Remove the proximity switch (2).