W DOC AIRBUS | AMM A320F

Removal of the Proximity Switches of the FWD Emergency Exits


TASK 52-73-11-000-003-B
Removal of the Proximity Switches of the FWD Emergency Exits


ZONE: 241
ZONE: 242
FIN: 5WN1 ** ON A/C NOT FOR ALL
FIN: 5WN2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
241
CENTER PASSENGER COMPARTMENT
242
CENTER PASSENGER COMPARTMENT
833, 834
FOR [5WN1] (PROX SW-HANDLE, L FWD EMER EXIT ESC SLIDE)
833CZ
FOR [5WN2] (PROX SW-HANDLE, R FWD EMER EXIT ESC SLIDE)
834CZ
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 52-22-00-010-002-A
Opening of the Emergency Exit Doors from the Outside
TASK 52-22-00-860-003-A
Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder
FOR [5WN1] (PROX SW-HANDLE, L FWD EMER EXIT ESC SLIDE)
TASK 25-23-47-000-012-A
Removal of the Door Linings of the LH FWD Emergency Exit Door, zone 231
FOR [5WN2] (PROX SW-HANDLE, R FWD EMER EXIT ESC SLIDE)
TASK 25-23-47-000-013-A
Removal of the Door Linings of the RH FWD Emergency Exit Door at zone 251 or RH AFT at zone 252 or LH AFT at zone 232.
3. Job Set-up
Subtask 52-73-11-861-055-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 52-73-11-010-054-A ** ON A/C NOT FOR ALL
B. Get Access
WARNING: STOP THE OPENING PROCEDURE IF THE RED WARNING LIGHT FLASHES. IF THE RED WARNING LIGHT FLASHES, REMAINING PRESSURE CAN CAUSE THE DOOR TO OPEN SUDDENLY AND CAN:
  • KILL OR CAUSE SERIOUS INJURY TO PERSONS
  • CAUSE DAMAGE TO THE AIRCRAFT.
   (1) Put an ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at the applicable emergency exit 833 or 834.
   (2) Open the applicable emergency exit 833 or 834 (Ref. AMM TASK 52-22-00-010-002).
   (3) Obey the special precautions before you start work on the emergency exit (Ref. AMM TASK 52-22-00-860-003).
Subtask 52-73-11-865-065-A ** ON A/C NOT FOR ALL
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
Subtask 52-73-11-010-061-A ** ON A/C NOT FOR ALL
D. Removal of the Lining Panel
   (1) Remove the lining panel:
     (a) FOR [5WN1] (PROX SW-HANDLE, L FWD EMER EXIT ESC SLIDE)
833CZ (Ref. AMM TASK 25-23-47-000-012).
     (b) FOR [5WN2] (PROX SW-HANDLE, R FWD EMER EXIT ESC SLIDE)
834CZ (Ref. AMM TASK 25-23-47-000-013).
   (2) Remove the insulation blanket.
4. Procedure
Subtask 52-73-11-020-058-A ** ON A/C NOT FOR ALL
A. Removal of the Proximity Switch
   (1) Disconnect the electrical connector (1) from the proximity switch (2).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove and discard the lockwire.
   (4) Remove the nut (4) and the washer (3).
   (5) Remove the proximity switch (2).
[Rev.10 from 2021] 2026.04.02 06:28:35 UTC