Operational Test of the Warning System Related to the Emergency Exit Doors
TASK 52-73-00-710-002-E
Operational Test of the Warning System Related to the Emergency Exit Doors
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-73-00-861-058-A ** ON A/C NOT FOR ALL Subtask 52-73-00-010-057-A ** ON A/C NOT FOR ALL
Subtask 52-73-00-710-059-A ** ON A/C NOT FOR ALL
(1) Do the tests that follow:
(2) Make sure that the clearance between the target and the related proximity switch is in the limits (Ref. AMM TASK 52-71-00-820-805).
(3) Do steps (1) and (2) again for the right overwing emergency-exit door
5. Close-up
Subtask 52-73-00-860-065-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:28:34 UTC
Operational Test of the Warning System Related to the Emergency Exit Doors
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| 98A52107632000 | 1 | PIN - SAFETY SLIDE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 833 | EMERGENCY EXITS |
| 834 | EMERGENCY EXITS |
| 835 | MID PASSENGER/CREW DOOR |
| 843 | EMERGENCY EXITS |
| 844 | EMERGENCY EXITS |
| 845 | MID PASSENGER/CREW DOOR |
| 835, 845 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 25-62-00-081-001-A | Special Precautions after Work on the Offwing Escape-Slide Systems |
| TASK 25-62-00-481-001-A | Special Precautions before Work on the Offwing Escape-Slide Systems |
| TASK 31-60-00-860-001-A | EIS Start Procedure |
| TASK 31-60-00-860-002-A | EIS Stop Procedure |
| TASK 52-22-00-010-002-A | Opening of the Emergency Exit Doors from the Outside |
| TASK 52-22-00-410-002-A | Closing of the Emergency Exit Doors from the Outside |
| TASK 52-22-00-860-003-A | Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder |
| TASK 52-22-00-860-004-A | Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder |
| TASK 52-71-00-820-007-A | Adjustment of the Proximity Switches of the Emergency Exit Doors with the Doors Checking Tool |
| TASK 52-71-00-820-007-A-01 | Adjustment of the Proximity Switches of the Emergency Exit Doors with the ECAM Display Unit (DU) |
| TASK 52-71-00-820-805-A | Adjustment of the Proximity Switches of the Overwing Emergency-Exit Door |
Subtask 52-73-00-861-058-A ** ON A/C NOT FOR ALL Subtask 52-73-00-010-057-A ** ON A/C NOT FOR ALL
B. Get Access
(1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position in front of emergency exit door 835( 845).
(2) Open the applicable emergency exit door (Ref. AMM TASK 52-22-00-010-002).
(3) Obey the special precautions before you start the work on the emergency exit door (Ref. AMM TASK 52-22-00-860-003).
(4) Close and lock the applicable emergency exit door.
Subtask 52-73-00-860-064-A ** ON A/C NOT FOR ALL (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position in front of emergency exit door 835( 845).
(2) Open the applicable emergency exit door (Ref. AMM TASK 52-22-00-010-002).
(3) Obey the special precautions before you start the work on the emergency exit door (Ref. AMM TASK 52-22-00-860-003).
(4) Close and lock the applicable emergency exit door.
C. Aircraft Maintenance Configuration
(1) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(2) On the ECAM control panel, push the DOOR key (the "DOOR/OXY" page comes into view).
(3) For the overwing emergency-exit doors, do the special precautions before you start the work on the offwing escape-slide systems (Ref. AMM TASK 25-62-00-481-001).
Subtask 52-73-00-865-072-A ** ON A/C NOT FOR ALL (1) Do the EIS start procedure (Ref. AMM TASK 31-60-00-860-001).
(2) On the ECAM control panel, push the DOOR key (the "DOOR/OXY" page comes into view).
(3) For the overwing emergency-exit doors, do the special precautions before you start the work on the offwing escape-slide systems (Ref. AMM TASK 25-62-00-481-001).
D. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SLIDES/ARM AND WARN/FLT | 15WN | P11 |
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/PAX | 48WV | P05 |
Subtask 52-73-00-710-059-A ** ON A/C NOT FOR ALL
A. Operational Test of the Warning System Related to the Emergency Exit Doors
(1) Do the tests that follow:
(2) Make sure that the clearance between the target and the related proximity switch is in the limits (Ref. AMM TASK 52-71-00-820-007).
(3) Do steps (1) and (2) again for the right emergency-exit door.
Subtask 52-73-00-710-058-A ** ON A/C NOT FOR ALL (1) Do the tests that follow:
| ACTION | RESULT |
|---|---|
1.On the left emergency-exit door:
| On the lower ECAM DU, on the "DOOR/OXY" page:
|
2.On the left emergency-exit door:
| On the lower ECAM DU, on the "DOOR/OXY" page:
|
3.On the left emergency-exit door:
| On the lower ECAM DU, on the "DOOR/OXY" page:
|
(3) Do steps (1) and (2) again for the right emergency-exit door.
NOTE: The test of the right emergency-exit door is the same as the test of the left emergency-exit door.
WARNING:
DO NOT OPEN THE EMERGENCY EXITS.
B. Operational Test of the Warning System Related to the Overwing Emergency-Exit Doors(1) Do the tests that follow:
| ACTION | RESULT |
|---|---|
1.On the forward left-overwing emergency-exit door:
| On the lower ECAM DU, on the "DOOR/OXY" page:
|
2.Disarm the slide release mechanism:
| On the lower ECAM DU, on the "DOOR/OXY" page:
|
3.On the aft left-overwing emergency-exit door:
| On the lower ECAM DU, on the "DOOR/OXY" page:
|
4.Disarm the slide release mechanism:
| In the cabin:
|
5.On the forward left-overwing emergency-exit door:
| In the cabin:
|
| On the lower ECAM DU, on the "DOOR/OXY" page:
|
6.On the aft left-overwing emergency-exit door:
| On the lower ECAM DU, on the "DOOR/OXY" page:
|
| On the lower ECAM DU, on the "DOOR/OXY" page:
|
(3) Do steps (1) and (2) again for the right overwing emergency-exit door
NOTE: The test of the right overwing emergency-exit doors is the same as the test of the left-overwing emergency-exit doors.
Subtask 52-73-00-860-065-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
(2) For the overwing emergency-exit doors, do the special precautions after work on the offwing escape-slide systems (Ref. AMM TASK 25-62-00-081-001).
Subtask 52-73-00-410-054-A ** ON A/C NOT FOR ALL (1) Do the EIS stop procedure (Ref. AMM TASK 31-60-00-860-002).
(2) For the overwing emergency-exit doors, do the special precautions after work on the offwing escape-slide systems (Ref. AMM TASK 25-62-00-081-001).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Obey the special precautions after the work on the applicable emergency exit door (Ref. AMM TASK 52-22-00-860-004).
(3) Close the applicable emergency exit door (Ref. AMM TASK 52-22-00-410-002).
(4) Remove the access platform(s).
Subtask 52-73-00-862-058-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Obey the special precautions after the work on the applicable emergency exit door (Ref. AMM TASK 52-22-00-860-004).
(3) Close the applicable emergency exit door (Ref. AMM TASK 52-22-00-410-002).
(4) Remove the access platform(s).
Emergency Exit Doors - Slide Release Mechanism