W DOC AIRBUS | AMM A320F

Removal of the Proximity Switches of the Avionics Compartment Doors


TASK 52-71-14-000-001-A
Removal of the Proximity Switches of the Avionics Compartment Doors


ZONE: 120
ZONE: 125
ZONE: 126
ZONE: 128
FIN: 23WV
FIN: 36WV
FIN: 38WV
FIN: 40WV
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
125
LATERAL AVIONIC COMPARTMENT
126
LATERAL AVIONIC COMPARTMENT
128
REAR AVIONIC COMPARTMENT
811, 812, 822, 824
FOR [23WV] (PROX SW-FRAME, L AVIONICS COMPT DOOR)
812
FOR [36WV] (PROX SW-FRAME, FWD AVIONICS COMPT DOOR)
811
FOR [38WV] (PROX SW-FRAME, R AVIONICS COMPT DOOR)
822
FOR [40WV] (PROX SW-FRAME, AFT AVIONICS COMPT DOOR)
128EG, 824
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
FOR [40WV] (PROX SW-FRAME, AFT AVIONICS COMPT DOOR)
TASK 53-12-13-000-001-A
Removal of the avionics compartment floor panels
3. Job Set-up
Subtask 52-71-14-860-050-A
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 52-71-14-865-050-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
49VUAIR COND/AVNCS VENT/CTL6HQD06
121VUEIS/SDAC1 AND 2/DOOR/DET/AVNCS46WVP02
Subtask 52-71-14-010-050-A
C. Get Access
   (1) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position in front of avionics compartment door 811, 812, 822 or 824.
   (2) Open the applicable avionics compartment door (Ref. AMM TASK 52-41-00-010-002):
     (a) FOR [36WV] (PROX SW-FRAME, FWD AVIONICS COMPT DOOR)
811
     (b) FOR [23WV] (PROX SW-FRAME, L AVIONICS COMPT DOOR)
812
     (c) FOR [38WV] (PROX SW-FRAME, R AVIONICS COMPT DOOR)
822
     (d) FOR [40WV] (PROX SW-FRAME, AFT AVIONICS COMPT DOOR)
824.
Subtask 52-71-14-020-051-B
D. Removal of Components
   (1) FOR [40WV] (PROX SW-FRAME, AFT AVIONICS COMPT DOOR)
Remove access panel 128EG (Ref. AMM TASK 53-12-13-000-001).
4. Procedure
Subtask 52-71-14-020-050-A
A. Removal of the Proximity Switch
   (1) Disconnect the electrical connector (1) from the proximity switch (2).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
   (3) Cut and discard the lockwire.
   (4) Remove the nut (5) and the washer (4).
   (5) Remove the proximity switch (2) from the support (3).