W DOC AIRBUS | AMM A320F

Installation of the Proximity Switches


TASK 52-71-13-400-002-A
Installation of the Proximity Switches


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 833
ZONE: 834
ZONE: 843
ZONE: 844
FIN: 19WV1 ** ON A/C NOT FOR ALL
FIN: 19WV2 ** ON A/C NOT FOR ALL
FIN: 21WV1 ** ON A/C NOT FOR ALL
FIN: 21WV2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
Torque wrench: range to between 2 and 0.2 m.daN (176.99 and 17.70 lbf.in ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.14QFB1)
Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
833
EMERGENCY EXITS
834
EMERGENCY EXITS
843
EMERGENCY EXITS
844
EMERGENCY EXITS
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 25-23-47-000-012-A
Removal of the Door Linings of the LH FWD Emergency Exit Door, zone 231
TASK 25-23-47-000-013-A
Removal of the Door Linings of the RH FWD Emergency Exit Door at zone 251 or RH AFT at zone 252 or LH AFT at zone 232.
TASK 25-23-47-000-802-A
Removal of the Door Linings of the Emergency Exit, zones 251/252
TASK 25-23-47-400-012-A
Installation of the Door Linings of the LH FWD Emergency Exit Door, zone 231
TASK 25-23-47-400-013-A
Installation of the Door Linings of the RH FWD Emergency Exit Door at zone 251, or RH AFT at zone 252, or LH AFT at zone 232.
TASK 25-23-47-400-802-A
Installation of the Door Linings of the Emergency Exit, zones 251/252
TASK 52-22-00-010-001-A
Opening of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-410-001-A
Closing of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-860-003-A
Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder
TASK 52-22-00-860-004-A
Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder
TASK 52-71-00-710-001-A
Operational Test of the Door Warning System
TASK 52-71-00-820-007-A
Adjustment of the Proximity Switches of the Emergency Exit Doors with the Doors Checking Tool
TASK 52-71-00-820-007-A-01
Adjustment of the Proximity Switches of the Emergency Exit Doors with the ECAM Display Unit (DU)
3. Job Set-up
Subtask 52-71-13-860-052-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the special precaution of the door damper and emergency operation cylinder is done (Ref. AMM TASK 52-22-00-860-003).
   (2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the open emergency exit door (referred to as door) (Ref. AMM TASK 52-22-00-010-001).
   (3) Make sure that the door lining is removed (Ref. AMM TASK 25-23-47-000-012) or (Ref. AMM TASK 25-23-47-000-013).
Subtask 52-71-13-860-052-B ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the special precaution of the door damper and emergency operation cylinder is done (Ref. AMM TASK 52-22-00-860-003).
   (2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the open emergency exit door (referred to as door) (Ref. AMM TASK 52-22-00-010-001).
   (3) Make sure that the door lining is removed (Ref. AMM TASK 25-23-47-000-802).
Subtask 52-71-13-865-057-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
4. Procedure
Subtask 52-71-13-420-051-A ** ON A/C NOT FOR ALL
A. Installation of the Proximity Switch
   (1) Clean the component interfaces and the adjacent area.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) Make sure that all the electrical connections are clean and in the correct condition.
   (4) Install the proximity sensor (2) as follows:
     (a) Put the proximity sensor (2) in position in the attachment bracket (3).
     (b) Install the lockwasher (9) and the locknut (8) on the proximity sensor (2).
     (c) Make sure that the lockwasher (9) is correctly engaged in the related hole of the attachment bracket (3).
     (d) TORQUE the locknut (8) to between 2 and 0.2 m.daN (176.99 and 17.70 lbf.in ) T.
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (e) Safety the locknut (8) and the lockwasher (9) with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
     (f) Remove the CAP-BLANKING from each electrical connector and receptacle.
     (g) Connect the connector (1) to the proximity sensor (2).
   (5) Install the target (4) as follows:
     (a) Install the target (4) on the shaft lever (5).
     (b) Install the lockwasher (6) and the locknut (7) on the target (4).
     (c) Do not tighten the locknut (7) at this time.
Subtask 52-71-13-820-051-A ** ON A/C NOT FOR ALL Subtask 52-71-13-865-053-A ** ON A/C NOT FOR ALL
C. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
Subtask 52-71-13-710-050-A ** ON A/C NOT FOR ALL
D. Operational Test
   (1) Do an operational test to make sure that the proximity switch operates correctly (Ref. AMM TASK 52-71-00-710-001).
5. Close-up
Subtask 52-71-13-410-052-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the door lining at the applicable section of the door (Ref. AMM TASK 25-23-47-400-012) or (Ref. AMM TASK 25-23-47-400-013).
   (3) Do the special precaution procedure on the door damper and emergency operation cylinder after work on the door (Ref. AMM TASK 52-22-00-860-004).
   (4) Close the emergency exit door (Ref. AMM TASK 52-22-00-410-001).
   (5) Remove the access platform(s).
Subtask 52-71-13-410-052-B ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Install the door lining at the applicable section of the door (Ref. AMM TASK 25-23-47-400-802).
   (3) Do the special precaution procedure on the door damper and emergency operation cylinder after work on the door (Ref. AMM TASK 52-22-00-860-004).
   (4) Close the emergency exit door (Ref. AMM TASK 52-22-00-410-001).
   (5) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.02 07:24:05 UTC