W DOC AIRBUS | AMM A320F

Removal of the Proximity Switches


TASK 52-71-13-000-002-A
Removal of the Proximity Switches


FIN: 19WV1 ** ON A/C NOT FOR ALL
FIN: 19WV2 ** ON A/C NOT FOR ALL
FIN: 21WV1 ** ON A/C NOT FOR ALL
FIN: 21WV2 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 25-23-47-000-012-A
Removal of the Door Linings of the LH FWD Emergency Exit Door, zone 231
TASK 25-23-47-000-013-A
Removal of the Door Linings of the RH FWD Emergency Exit Door at zone 251 or RH AFT at zone 252 or LH AFT at zone 232.
TASK 25-23-47-000-802-A
Removal of the Door Linings of the Emergency Exit, zones 251/252
TASK 52-22-00-010-001-A
Opening of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-860-003-A
Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder
3. Job Set-up
WARNING: BEFORE YOU START WORK ON THE DOOR, MAKE SURE THAT:
  • THE EMERGENCY CONTROL HANDLE IS IN THE DISARMED POSITION WITH THE SAFETY PIN INSTALLED.
  • THE PERCUSSION LEVER OF THE DOOR-DAMPER AND EMERGENCY-OPERATION CYLINDER IS IN THE DISARMED POSITION WITH THE SAFETY PIN INSTALLED.
IF YOU DO NOT OBEY THESE INSTRUCTIONS, THE DOOR CAN OPEN WITH FORCE OR THE ESCAPE SLIDE CAN DEPLOY SUDDENLY. THIS CAN CAUSE INJURY AND/OR DAMAGE.
Subtask 52-71-13-865-052-A ** ON A/C NOT FOR ALL
A. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
Subtask 52-71-13-010-052-A ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the emergency exit door (referred to as door) (Ref. AMM TASK 52-22-00-010-001).
   (2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the open door.
   (3) Make sure that the special precaution procedure on the door damper and emergency operation cylinder is done (Ref. AMM TASK 52-22-00-860-003).
   (4) Remove the door lining from the applicable section of the door (Ref. AMM TASK 25-23-47-000-013) and (Ref. AMM TASK 25-23-47-000-012).
Subtask 52-71-13-010-052-B ** ON A/C NOT FOR ALL
B. Get Access
   (1) Open the emergency exit door (referred to as door) (Ref. AMM TASK 52-22-00-010-001).
   (2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the open door.
   (3) Make sure that the special precaution procedure on the door damper and emergency operation cylinder is done (Ref. AMM TASK 52-22-00-860-003).
   (4) Remove the door lining from the applicable section of the door (Ref. AMM TASK 25-23-47-000-802).
4. Procedure
Subtask 52-71-13-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Proximity Switch
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
   (1) Remove the proximity sensor (2) as follows:
     (a) Disconnect the electrical connector (1) from the proximity sensor (2).
     (b) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
     (c) Remove and discard the lockwire from the locknut (8).
     (d) Remove the locknut (8) with the lockwasher (9).
     (e) Remove the proximity sensor (2) from the attachment bracket (3).
   (2) Remove the target (4) as follows:
     (a) Remove and discard the lockwire from the locknut (7).
     (b) Remove the locknut (7) and the lockwasher (6) from the target (4).
     (c) Remove the target (4) from the shaft lever (5).
[Rev.10 from 2021] 2026.04.02 06:28:33 UTC