Removal of the Proximity Switches
TASK 52-71-13-000-002-A
Removal of the Proximity Switches
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 52-71-13-020-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:28:33 UTC
Removal of the Proximity Switches
FIN: 19WV1 ** ON A/C NOT FOR ALL
FIN: 19WV2 ** ON A/C NOT FOR ALL
FIN: 21WV1 ** ON A/C NOT FOR ALL
FIN: 21WV2 ** ON A/C NOT FOR ALL
1. Reason for the JobFIN: 19WV2 ** ON A/C NOT FOR ALL
FIN: 21WV1 ** ON A/C NOT FOR ALL
FIN: 21WV2 ** ON A/C NOT FOR ALL
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 25-23-47-000-012-A | Removal of the Door Linings of the LH FWD Emergency Exit Door, zone 231 |
| TASK 25-23-47-000-013-A | Removal of the Door Linings of the RH FWD Emergency Exit Door at zone 251 or RH AFT at zone 252 or LH AFT at zone 232. |
| TASK 25-23-47-000-802-A | Removal of the Door Linings of the Emergency Exit, zones 251/252 |
| TASK 52-22-00-010-001-A | Opening of the Emergency Exit Doors from the Passenger Compartment |
| TASK 52-22-00-860-003-A | Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder |
WARNING:
BEFORE YOU START WORK ON THE DOOR, MAKE SURE THAT:
Subtask 52-71-13-865-052-A ** ON A/C NOT FOR ALL - THE EMERGENCY CONTROL HANDLE IS IN THE DISARMED POSITION WITH THE SAFETY PIN INSTALLED.
- THE PERCUSSION LEVER OF THE DOOR-DAMPER AND EMERGENCY-OPERATION CYLINDER IS IN THE DISARMED POSITION WITH THE SAFETY PIN INSTALLED.
A. Open, safety and tag this(these) circuit breaker(s):
Subtask 52-71-13-010-052-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SLIDES/ARM AND WARN/FLT | 15WN | P11 |
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/PAX | 48WV | P05 |
B. Get Access
(1) Open the emergency exit door (referred to as door) (Ref. AMM TASK 52-22-00-010-001).
(2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the open door.
(3) Make sure that the special precaution procedure on the door damper and emergency operation cylinder is done (Ref. AMM TASK 52-22-00-860-003).
(4) Remove the door lining from the applicable section of the door (Ref. AMM TASK 25-23-47-000-013) and (Ref. AMM TASK 25-23-47-000-012).
Subtask 52-71-13-010-052-B ** ON A/C NOT FOR ALL (1) Open the emergency exit door (referred to as door) (Ref. AMM TASK 52-22-00-010-001).
(2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the open door.
(3) Make sure that the special precaution procedure on the door damper and emergency operation cylinder is done (Ref. AMM TASK 52-22-00-860-003).
(4) Remove the door lining from the applicable section of the door (Ref. AMM TASK 25-23-47-000-013) and (Ref. AMM TASK 25-23-47-000-012).
B. Get Access
(1) Open the emergency exit door (referred to as door) (Ref. AMM TASK 52-22-00-010-001).
(2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the open door.
(3) Make sure that the special precaution procedure on the door damper and emergency operation cylinder is done (Ref. AMM TASK 52-22-00-860-003).
(4) Remove the door lining from the applicable section of the door (Ref. AMM TASK 25-23-47-000-802).
4. Procedure(1) Open the emergency exit door (referred to as door) (Ref. AMM TASK 52-22-00-010-001).
(2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the open door.
(3) Make sure that the special precaution procedure on the door damper and emergency operation cylinder is done (Ref. AMM TASK 52-22-00-860-003).
(4) Remove the door lining from the applicable section of the door (Ref. AMM TASK 25-23-47-000-802).
Subtask 52-71-13-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Proximity Switch
Proximity Switch / Target Adjustment ** ON A/C NOT FOR ALL
Proximity Switch / Target Adjustment ** ON A/C NOT FOR ALL
(a) Disconnect the electrical connector (1) from the proximity sensor (2).
(b) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(c) Remove and discard the lockwire from the locknut (8).
(d) Remove the locknut (8) with the lockwasher (9).
(e) Remove the proximity sensor (2) from the attachment bracket (3).
(2) Remove the target (4) as follows:
(a) Remove and discard the lockwire from the locknut (7).
(b) Remove the locknut (7) and the lockwasher (6) from the target (4).
(c) Remove the target (4) from the shaft lever (5).
Proximity Switch / Target Adjustment ** ON A/C NOT FOR ALL
Proximity Switch / Target Adjustment ** ON A/C NOT FOR ALL WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(1) Remove the proximity sensor (2) as follows: (a) Disconnect the electrical connector (1) from the proximity sensor (2).
(b) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(c) Remove and discard the lockwire from the locknut (8).
(d) Remove the locknut (8) with the lockwasher (9).
(e) Remove the proximity sensor (2) from the attachment bracket (3).
(2) Remove the target (4) as follows:
(a) Remove and discard the lockwire from the locknut (7).
(b) Remove the locknut (7) and the lockwasher (6) from the target (4).
(c) Remove the target (4) from the shaft lever (5).