W DOC AIRBUS | AMM A320F

Adjustment of the Proximity Switches of the Overwing Emergency-Exit Door


TASK 52-71-00-820-805-A
Adjustment of the Proximity Switches of the Overwing Emergency-Exit Door


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
FIN: 31WN1 ** ON A/C NOT FOR ALL
FIN: 31WN2 ** ON A/C NOT FOR ALL
FIN: 31WN3 ** ON A/C NOT FOR ALL
FIN: 31WN4 ** ON A/C NOT FOR ALL
FIN: 32WN1 ** ON A/C NOT FOR ALL
FIN: 32WN2 ** ON A/C NOT FOR ALL
FIN: 32WN3 ** ON A/C NOT FOR ALL
FIN: 32WN4 ** ON A/C NOT FOR ALL
FIN: 33WN1 ** ON A/C NOT FOR ALL
FIN: 33WN2 ** ON A/C NOT FOR ALL
FIN: 33WN3 ** ON A/C NOT FOR ALL
FIN: 33WN4 ** ON A/C NOT FOR ALL
FIN: 34WN1 ** ON A/C NOT FOR ALL
FIN: 34WN2 ** ON A/C NOT FOR ALL
FIN: 34WN3 ** ON A/C NOT FOR ALL
FIN: 34WN4 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
WARNING NOTICE(S)
FOR [31WN1] (PROX SW-LOCK 1, L FWD OVERWING DOOR)
FOR [31WN2] (PROX SW-LOCK 1, R FWD OVERWING DOOR)
FOR [31WN3] (PROX SW-LOCK 1, L AFT OVERWING DOOR)
FOR [31WN4] (PROX SW-LOCK 1, R AFT OVERWING DOOR)
FOR [32WN1] (PROX SW-LOCK 2, L FWD OVERWING DOOR)
FOR [32WN2] (PROX SW-LOCK 2, R FWD OVERWING DOOR)
FOR [32WN3] (PROX SW-LOCK 2, L AFT OVERWING DOOR)
FOR [32WN4] (PROX SW-LOCK 2, R AFT OVERWING DOOR)
FOR [34WN1] (PROX SW-ESC SLIDE HANDLE, L FWD OVERWING DOOR)
FOR [34WN2] (PROX SW-ESC SLIDE HANDLE, R FWD OVERWING DOOR)
FOR [34WN3] (PROX SW-ESC SLIDE HANDLE, L AFT OVERWING DOOR)
FOR [34WN4] (PROX SW-ESC SLIDE HANDLE, R AFT OVERWING DOOR)
No specific
1
GAGE - FEELER
FOR [33WN1] (PROX SW-HANDLE FLAP, L FWD OVERWING DOOR)
FOR [33WN2] (PROX SW-HANDLE FLAP, R FWD OVERWING DOOR)
FOR [33WN3] (PROX SW-HANDLE FLAP, L AFT OVERWING DOOR)
FOR [33WN4] (PROX SW-HANDLE FLAP, R AFT OVERWING DOOR)
No specific
1
CALIPER
 B. Consumable Materials
REFERENCE
DESIGNATION
FOR [33WN1] (PROX SW-HANDLE FLAP, L FWD OVERWING DOOR)
FOR [33WN2] (PROX SW-HANDLE FLAP, R FWD OVERWING DOOR)
FOR [33WN3] (PROX SW-HANDLE FLAP, L AFT OVERWING DOOR)
FOR [33WN4] (PROX SW-HANDLE FLAP, R AFT OVERWING DOOR)
(Material No.14VGF1)
Individual Compound-- Modeling Paste -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
833, 834, 843, 844
FOR [31WN1] (PROX SW-LOCK 1, L FWD OVERWING DOOR)
FOR [31WN2] (PROX SW-LOCK 1, R FWD OVERWING DOOR)
FOR [31WN3] (PROX SW-LOCK 1, L AFT OVERWING DOOR)
FOR [31WN4] (PROX SW-LOCK 1, R AFT OVERWING DOOR)
FOR [32WN1] (PROX SW-LOCK 2, L FWD OVERWING DOOR)
FOR [32WN2] (PROX SW-LOCK 2, R FWD OVERWING DOOR)
FOR [32WN3] (PROX SW-LOCK 2, L AFT OVERWING DOOR)
FOR [32WN4] (PROX SW-LOCK 2, R AFT OVERWING DOOR)
FOR [34WN1] (PROX SW-ESC SLIDE HANDLE, L FWD OVERWING DOOR)
FOR [34WN2] (PROX SW-ESC SLIDE HANDLE, R FWD OVERWING DOOR)
FOR [34WN3] (PROX SW-ESC SLIDE HANDLE, L AFT OVERWING DOOR)
FOR [34WN4] (PROX SW-ESC SLIDE HANDLE, R AFT OVERWING DOOR)
833, 833AZ, 834, 834AZ, 843, 843AZ, 844, 844AZ
FOR [33WN1] (PROX SW-HANDLE FLAP, L FWD OVERWING DOOR)
FOR [33WN2] (PROX SW-HANDLE FLAP, R FWD OVERWING DOOR)
FOR [33WN3] (PROX SW-HANDLE FLAP, L AFT OVERWING DOOR)
FOR [33WN4] (PROX SW-HANDLE FLAP, R AFT OVERWING DOOR)
833, 833AZ, 834, 834AZ, 843, 843AZ, 844, 844AZ
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 25-62-00-081-001-A
Special Precautions after Work on the Offwing Escape-Slide Systems
TASK 25-62-00-481-001-A
Special Precautions before Work on the Offwing Escape-Slide Systems
TASK 52-22-00-410-802-A
Closing of the Overwing Emergency-Exit Door from the Passenger Compartment
TASK 52-73-00-710-002-E
Operational Test of the Warning System Related to the Emergency Exit Doors
FOR [31WN1] (PROX SW-LOCK 1, L FWD OVERWING DOOR)
FOR [31WN2] (PROX SW-LOCK 1, R FWD OVERWING DOOR)
FOR [31WN3] (PROX SW-LOCK 1, L AFT OVERWING DOOR)
FOR [31WN4] (PROX SW-LOCK 1, R AFT OVERWING DOOR)
FOR [32WN1] (PROX SW-LOCK 2, L FWD OVERWING DOOR)
FOR [32WN2] (PROX SW-LOCK 2, R FWD OVERWING DOOR)
FOR [32WN3] (PROX SW-LOCK 2, L AFT OVERWING DOOR)
FOR [32WN4] (PROX SW-LOCK 2, R AFT OVERWING DOOR)
FOR [34WN1] (PROX SW-ESC SLIDE HANDLE, L FWD OVERWING DOOR)
FOR [34WN2] (PROX SW-ESC SLIDE HANDLE, R FWD OVERWING DOOR)
FOR [34WN3] (PROX SW-ESC SLIDE HANDLE, L AFT OVERWING DOOR)
FOR [34WN4] (PROX SW-ESC SLIDE HANDLE, R AFT OVERWING DOOR)
TASK 25-23-47-000-803-A
Removal of the Door Lining from the Overwing Emergency Exit
TASK 25-23-47-400-803-A
Installation of the Door Lining on the Overwing Emergency Exit
FOR [33WN1] (PROX SW-HANDLE FLAP, L FWD OVERWING DOOR)
FOR [33WN2] (PROX SW-HANDLE FLAP, R FWD OVERWING DOOR)
FOR [33WN3] (PROX SW-HANDLE FLAP, L AFT OVERWING DOOR)
FOR [33WN4] (PROX SW-HANDLE FLAP, R AFT OVERWING DOOR)
TASK 25-23-47-400-803-A
Installation of the Door Lining on the Overwing Emergency Exit
3. Job Set-up
Subtask 52-71-00-860-075-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) On the overhead panel, on the SIGNS section of control panel 25VU, make sure that:
  • The EMER EXIT LT switch is in the OFF position.
  • The NO PED switch is in the OFF position.
   (3) Put the WARNING NOTICE(S) in position to tell persons not to operate these switches.
   (4) On Flight Attendant Panel (FAP) 120RH, make sure that the EMER button and its light are off.
   (5) Make sure that applicable overwing emergency-exit door 833 ( 843) or 834 ( 844) is closed, latched and locked (Ref. AMM TASK 52-22-00-410-802).
   (6) Do the special precaution before you do work on the offwing escape-slide systems:
WARNING: MAKE SURE THAT THE LOCK PIN IS CORRECTLY INSTALLED IN THE REGULATOR VALVE ASSEMBLY OF THE INFLATION RESERVOIR. THIS SAFETIES ALL COMPONENTS OF THE INFLATION SYSTEM IN OPERATION AND PREVENTS ACCIDENTAL:
  • DISCHARGE OF THE INFLATION RESERVOIR
  • DEPLOYMENT OF THE ESCAPE SLIDE
WHICH CAN CAUSE INJURY AND/OR DAMAGE.
     (a) Do the special precaution before you do work on the offwing escape-slide systems (Ref. AMM TASK 25-62-00-481-001).
Subtask 52-71-00-865-091-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VULIGHTING/EMER LT/CABIN2WLH04
49VULIGHTING/EMER LT/CABIN1WLH03
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
122VUFLIGHT LOCK OWD40WNU16
122VULIGHTING/CABIN/EMER/LT3WLV07
Subtask 52-71-00-010-101-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) FOR [31WN1] (PROX SW-LOCK 1, L FWD OVERWING DOOR), [31WN2] (PROX SW-LOCK 1, R FWD OVERWING DOOR), [31WN3] (PROX SW-LOCK 1, L AFT OVERWING DOOR), [31WN4] (PROX SW-LOCK 1, R AFT OVERWING DOOR), [32WN1] (PROX SW-LOCK 2, L FWD OVERWING DOOR), [32WN2] (PROX SW-LOCK 2, R FWD OVERWING DOOR), [32WN3] (PROX SW-LOCK 2, L AFT OVERWING DOOR), [32WN4] (PROX SW-LOCK 2, R AFT OVERWING DOOR), [34WN1] (PROX SW-ESC SLIDE HANDLE, L FWD OVERWING DOOR), [34WN2] (PROX SW-ESC SLIDE HANDLE, R FWD OVERWING DOOR), [34WN3] (PROX SW-ESC SLIDE HANDLE, L AFT OVERWING DOOR), [34WN4] (PROX SW-ESC SLIDE HANDLE, R AFT OVERWING DOOR)
   (2) FOR [33WN1] (PROX SW-HANDLE FLAP, L FWD OVERWING DOOR), [33WN2] (PROX SW-HANDLE FLAP, R FWD OVERWING DOOR), [33WN3] (PROX SW-HANDLE FLAP, L AFT OVERWING DOOR), [33WN4] (PROX SW-HANDLE FLAP, R AFT OVERWING DOOR)
     (a) Make sure that door lining (8) 833AZ ( 843AZ) or 834AZ ( 844AZ) of overwing emergency-exit door 833 ( 843) or 834 ( 844) is installed (Ref. AMM TASK 25-23-47-400-803).
     (b) Open and remove the handle cover (9).
4. Procedure
Subtask 52-71-00-820-087-D ** ON A/C NOT FOR ALL
A. Adjustment of the Proximity Switches of the Overwing Emergency-Exit Door
   (1) FOR [31WN1] (PROX SW-LOCK 1, L FWD OVERWING DOOR), [31WN2] (PROX SW-LOCK 1, R FWD OVERWING DOOR), [31WN3] (PROX SW-LOCK 1, L AFT OVERWING DOOR), [31WN4] (PROX SW-LOCK 1, R AFT OVERWING DOOR), [32WN1] (PROX SW-LOCK 2, L FWD OVERWING DOOR), [32WN2] (PROX SW-LOCK 2, R FWD OVERWING DOOR), [32WN3] (PROX SW-LOCK 2, L AFT OVERWING DOOR), [32WN4] (PROX SW-LOCK 2, R AFT OVERWING DOOR), [34WN1] (PROX SW-ESC SLIDE HANDLE, L FWD OVERWING DOOR), [34WN2] (PROX SW-ESC SLIDE HANDLE, R FWD OVERWING DOOR), [34WN3] (PROX SW-ESC SLIDE HANDLE, L AFT OVERWING DOOR), [34WN4] (PROX SW-ESC SLIDE HANDLE, R AFT OVERWING DOOR)
     (a) Measure clearance A between the target (5) and the proximity switch (4) with the GAGE - FEELER.
     (b) Make sure that clearance A is 2 +0.15 mm or -0.15 mm (0.0787 +0.0059 in. or -0.0059 in.).
     (c) If clearance A is out of tolerances, go to the step (3).
   (2) FOR [33WN1] (PROX SW-HANDLE FLAP, L FWD OVERWING DOOR), [33WN2] (PROX SW-HANDLE FLAP, R FWD OVERWING DOOR), [33WN3] (PROX SW-HANDLE FLAP, L AFT OVERWING DOOR), [33WN4] (PROX SW-HANDLE FLAP, R AFT OVERWING DOOR)
     (a) Apply Individual Compound-- Modeling Paste - (Material No.14VGF1) to the tip of the proximity switch (4).
     (b) Close the handle cover (9) to a clearance of approximately 10 mm (0.3937 in.) at its upper edge.
     (c) Open and remove the handle cover (9).
     (d) Measure the thickness of the compressed putty with the CALIPER.
NOTE: This is related to clearance A between the target (5) and the proximity switch (4).
     (e) Make sure that clearance A is 1.5 -0.5 MM or +0.5 MM (0.0591 -0.0197 IN. or +0.0197 IN.).
     (f) If clearance A is out of tolerances, go to step (4).
     (g) Remove the putty from the proximity switch (4).
     (h) Install the handle cover (9).
   (3) FOR [31WN1] (PROX SW-LOCK 1, L FWD OVERWING DOOR), [31WN2] (PROX SW-LOCK 1, R FWD OVERWING DOOR), [31WN3] (PROX SW-LOCK 1, L AFT OVERWING DOOR), [31WN4] (PROX SW-LOCK 1, R AFT OVERWING DOOR), [32WN1] (PROX SW-LOCK 2, L FWD OVERWING DOOR), [32WN2] (PROX SW-LOCK 2, R FWD OVERWING DOOR), [32WN3] (PROX SW-LOCK 2, L AFT OVERWING DOOR), [32WN4] (PROX SW-LOCK 2, R AFT OVERWING DOOR), [34WN1] (PROX SW-ESC SLIDE HANDLE, L FWD OVERWING DOOR), [34WN2] (PROX SW-ESC SLIDE HANDLE, R FWD OVERWING DOOR), [34WN3] (PROX SW-ESC SLIDE HANDLE, L AFT OVERWING DOOR), [34WN4] (PROX SW-ESC SLIDE HANDLE, R AFT OVERWING DOOR)
  • If clearance A is not in the tolerances, adjust it as follows:
     (a) Unfold the lockwasher (2) from the bracket (1) and the nut (3).
     (b) Loosen the nut (3) of the target (5).
     (c) Turn the target (5) until clearance A is 2 +0.15 mm or -0.15 mm (0.0787 +0.0059 in. or -0.0059 in.).
     (d) Tighten the nut (3).
     (e) Fold the lockwasher (2) on the nut (3) and the bracket (1).
   (4) FOR [33WN1] (PROX SW-HANDLE FLAP, L FWD OVERWING DOOR), [33WN2] (PROX SW-HANDLE FLAP, R FWD OVERWING DOOR), [33WN3] (PROX SW-HANDLE FLAP, L AFT OVERWING DOOR), [33WN4] (PROX SW-HANDLE FLAP, R AFT OVERWING DOOR)
  • If clearance A is not in the tolerances, adjust it as follows:
     (a) Loosen the two screws (7).
     (b) Adjust the bracket (6) until clearance A is in the tolerances.
     (c) Tighten the screws (7).
     (d) Apply Individual Compound-- Modeling Paste - (Material No.14VGF1) to the tip of the proximity switch (4).
     (e) Close the handle cover (9) to a clearance of approximately 10 mm (0.3937 in.) at its upper edge.
     (f) Open and remove the handle cover (9).
     (g) Measure the thickness of the compressed putty with the CALIPER.
NOTE: This is related to clearance A between the target (5) and the proximity switch (4).
     (h) Make sure that clearance A is 1.5 -0.5 MM or +0.5 MM (0.0591 -0.0197 IN. or +0.0197 IN.).
     (i) If necessary, do the steps (a) thru (h) again.
     (j) Remove the putty from the proximity switch (4).
     (k) Install the handle cover (9).
Subtask 52-71-00-865-092-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VULIGHTING/EMER LT/CABIN2WLH04
49VULIGHTING/EMER LT/CABIN1WLH03
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
122VUFLIGHT LOCK OWD40WNU16
122VULIGHTING/CABIN/EMER/LT3WLV07
Subtask 52-71-00-710-077-A ** ON A/C NOT FOR ALL
C. Operational Test
   (1) FOR [31WN1] (PROX SW-LOCK 1, L FWD OVERWING DOOR), [31WN2] (PROX SW-LOCK 1, R FWD OVERWING DOOR), [31WN3] (PROX SW-LOCK 1, L AFT OVERWING DOOR), [31WN4] (PROX SW-LOCK 1, R AFT OVERWING DOOR), [32WN1] (PROX SW-LOCK 2, L FWD OVERWING DOOR), [32WN2] (PROX SW-LOCK 2, R FWD OVERWING DOOR), [32WN3] (PROX SW-LOCK 2, L AFT OVERWING DOOR), [32WN4] (PROX SW-LOCK 2, R AFT OVERWING DOOR), [34WN1] (PROX SW-ESC SLIDE HANDLE, L FWD OVERWING DOOR), [34WN2] (PROX SW-ESC SLIDE HANDLE, R FWD OVERWING DOOR), [34WN3] (PROX SW-ESC SLIDE HANDLE, L AFT OVERWING DOOR), [34WN4] (PROX SW-ESC SLIDE HANDLE, R AFT OVERWING DOOR)
   (2) On the ECAM SD, make sure that the overwing emergency-exit door is shown closed (green).
   (3) Do an operational test of the warning system related to the overwing emergency-exit door (Ref. AMM TASK 52-73-00-710-002).
5. Close-up
Subtask 52-71-00-410-104-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Remove the WARNING NOTICE(S).
Subtask 52-71-00-860-076-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) Do the special precautions after you did work on the offwing escape-slide systems (Ref. AMM TASK 25-62-00-081-001).
   (2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 07:22:52 UTC