W DOC AIRBUS | AMM A320F

Adjustment of the Proximity Switch of the Avionics Compartment Door 822


TASK 52-71-00-820-011-A
Adjustment of the Proximity Switch of the Avionics Compartment Door 822


FIN: 38WV
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
TASK 52-71-00-710-001-A
Operational Test of the Door Warning System
3. Job Set-up
Subtask 52-71-00-861-070-A
A. Energize the ground service network (Ref. AMM TASK 24-42-00-861-001).
Subtask 52-71-00-010-087-A
B. Get Access
   (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position in front of the avionics compartment door 822.
   (2) Open the avionics compartment door 822 (Ref. AMM TASK 52-41-00-010-002).
4. Procedure
Subtask 52-71-00-820-080-A
A. Adjustment of the Proximity Switch
WARNING: DO NOT OPEN THE DOOR DURING THE ADJUSTMENT.
   (1) Make sure that the door is open.
   (2) Disconnect the electrical connector of the proximity switch.
   (3) Put blanking caps on the disconnected electrical connectors.
   (4) Measure the clearance J2 between the target (1) and the proximity sensor (2).
  • The clearance J2 must be 5.2 mm (0.2047 in.) min.
   (5) Close the avionics compartment door 822 (Ref. AMM TASK 52-41-00-410-002).
   (6) Measure the clearance J1 between the target (1) and the proximity sensor (2).
  • The clearance J1 must be 1 -0.5 mm or +0.5 mm (0.0394 -0.0197 in. or +0.0197 in.).
   (7) If the clearance J1 is not in the tolerances, adjust as follows:
     (a) Loosen the screws (3), (4), (5) until you can move the support assembly. Adjust the position of the proximity switch to get the correct clearance J1.
NOTE: The target (1) and the proximity sensor (2) must not touch.
     (b) Tighten the screws (3), (4), (5).
   (8) Connect the electrical connector of the proximity switch.
Subtask 52-71-00-710-070-A
B. Operational test
   (1) Do an operational test of the door warning system related to the avionics compartment doors (Ref. AMM TASK 52-71-00-710-001).
5. Close-up
Subtask 52-71-00-410-091-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Open the avionics compartment door 822 (Ref. AMM TASK 52-41-00-010-002).
   (3) Go out of the avionics compartment.
   (4) Close the avionics compartment door 822 (Ref. AMM TASK 52-41-00-410-002).
   (5) Remove the access platform(s).
Subtask 52-71-00-862-071-A
B. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.02 06:28:31 UTC