W DOC AIRBUS | AMM A320F

Adjustment of the Proximity Switches of the Avionics Compartment Doors 811, 812 and 824


TASK 52-71-00-820-008-A
Adjustment of the Proximity Switches of the Avionics Compartment Doors 811, 812 and 824


FIN: 23WV
FIN: 36WV
FIN: 40WV
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
Torque wrench: range to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.14QFB1)
Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
811, 812, 824
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 52-41-00-010-002-A
Open the Avionics Compartment Doors for Access
TASK 52-41-00-410-002-A
Close the Avionics Compartment Doors after Access
TASK 52-71-00-710-001-A
Operational Test of the Door Warning System
FOR [36WV] (PROX SW-FRAME, FWD AVIONICS COMPT DOOR)
TASK 53-12-13-000-001-A
Removal of the avionics compartment floor panels
TASK 53-12-13-400-001-A
Installation of the avionics compartment floor panels
FOR [40WV] (PROX SW-FRAME, AFT AVIONICS COMPT DOOR)
TASK 53-12-13-000-001-A
Removal of the avionics compartment floor panels
TASK 53-12-13-400-001-A
Installation of the avionics compartment floor panels
3. Job Set-up
Subtask 52-71-00-861-062-A
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 52-71-00-010-075-A
B. Get Access
   (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position in front of the applicable avionics compartment door.
   (2) Open the applicable avionics compartment door 811 or 812 or 824 (Ref. AMM TASK 52-41-00-010-002).
Subtask 52-71-00-865-063-A
C. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUEIS/SDAC1 AND 2/DOOR/DET/AVNCS46WVP02
Subtask 52-71-00-020-058-A
D. Removal of Components
   (1) FOR [36WV] (PROX SW-FRAME, FWD AVIONICS COMPT DOOR)
     (a) Remove the access panel 121CF (Ref. AMM TASK 53-12-13-000-001)
   (2) FOR [40WV] (PROX SW-FRAME, AFT AVIONICS COMPT DOOR)
     (a) Remove the access panel 128EG (Ref. AMM TASK 53-12-13-000-001)
4. Procedure
Subtask 52-71-00-820-071-A
A. Adjustment of the Proximity Switch
WARNING: DO NOT OPEN THE DOOR DURING THE ADJUSTMENT.
   (1) Make sure that the door is open.
   (2) Disconnect the electrical connector of the proximity switch (1).
   (3) Put blanking caps on the disconnected electrical connectors.
   (4) Measure the clearance J2 between the target (2) and the proximity switch (1).
  • The clearance J2 must be 5.2 mm (0.2047 in.) min.
   (5) Close the applicable avionics compartment door 811, 812 or 824 (Ref. AMM TASK 52-41-00-410-002).
     (a) Make sure that you turn the handle fully and push it into the recess.
   (6) Measure the clearance J1 between the target (2) and the proximity switch (1).
  • The clearance J1 must be 1 -0.5 mm or +0.5 mm (0.0394 -0.0197 in. or +0.0197 in.).
   (7) If the clearance J1 is not in the tolerances, adjust as follows:
     (a) Cut the lockwire from the nut (3).
     (b) Loosen the nut (3) of the target (2).
     (c) Turn the target (2) until to get the correct clearance J1.
NOTE: The target (2) and the proximity switch (1) must not touch.
     (d) TORQUE the nut (3) to between 0.7 and 0.6 m.daN (61.95 and 53.10 lbf.in ) T.
     (e) Safety the nut (3) with 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
   (8) Remove the blanking caps from the electrical connector(s).
   (9) Connect the electrical connector of the proximity switch (1) to its related connector.
Subtask 52-71-00-865-064-A
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C ALL
121VUEIS/SDAC1 AND 2/DOOR/DET/AVNCS46WVP02
Subtask 52-71-00-710-063-A
5. Close-up
Subtask 52-71-00-420-060-A
A. Installation of Components
   (1) FOR [36WV] (PROX SW-FRAME, FWD AVIONICS COMPT DOOR)
     (a) Install the access panel 121CF (Ref. AMM TASK 53-12-13-400-001).
   (2) FOR [40WV] (PROX SW-FRAME, AFT AVIONICS COMPT DOOR)
     (a) Install the access panel 128EG (Ref. AMM TASK 53-12-13-400-001).
Subtask 52-71-00-410-079-A
B. Close Access
   (1) Make sure that the work area is clean and clear of tool(s) and other items.
   (2) Open the applicable avionics compartment door 811 or 812 or 824 (Ref. AMM TASK 52-41-00-010-002).
   (3) Go out of the avionics compartment.
   (4) Close the applicable avionics compartment door 811 or
812 or
or 824 (Ref. AMM TASK 52-41-00-410-002).
   (5) Remove the access platform(s).
Subtask 52-71-00-862-063-A
C. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.02 07:24:15 UTC