W DOC AIRBUS | AMM A320F

Adjustment of the Proximity Switches of the Emergency Exit Doors with the Doors Checking Tool


TASK 52-71-00-820-007-A
Adjustment of the Proximity Switches of the Emergency Exit Doors with the Doors Checking Tool


WARNING: STOP THE OPENING PROCEDURE IF THE RED WARNING LIGHT FLASHES. IF THE RED WARNING LIGHT FLASHES, REMAINING PRESSURE CAN CAUSE THE DOOR TO OPEN SUDDENLY AND CAN:
  • KILL OR CAUSE SERIOUS INJURY TO PERSONS
  • CAUSE DAMAGE TO THE AIRCRAFT.
1. Reason for the Job
There are two methods to do the adjustment of the proximity switches of the emergency exit doors:
  • Mechanically - with the doors checking tool
  • Electronically - with the ECAM Display Unit (DU).
This task gives the mechanical method. For the other method, refer to the related task in this page block.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
355M03210000
1
CHECKING TOOL-DOORS
G55M03210000
1
CHECKING TOOL - DOORS
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
843EZ, 844EZ
833AZ, 834AZ, 835, 845
833, 833EZ, 834, 834EZ, 843, 844
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
5
LOCK WASHER
AIPC 52-22-21-09-218
5
LOCK WASHER
AIPC 52-22-21-09-615
5
LOCK WASHER
AIPC 52-22-21-24-430
5
LOCK WASHER
AIPC 52-22-21-24-690
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 25-23-47-000-013-A
Removal of the Door Linings of the RH FWD Emergency Exit Door at zone 251 or RH AFT at zone 252 or LH AFT at zone 232.
TASK 25-23-47-000-802-A
Removal of the Door Linings of the Emergency Exit, zones 251/252
TASK 25-23-47-400-013-A
Installation of the Door Linings of the RH FWD Emergency Exit Door at zone 251, or RH AFT at zone 252, or LH AFT at zone 232.
TASK 25-23-47-400-802-A
Installation of the Door Linings of the Emergency Exit, zones 251/252
TASK 52-22-00-010-002-A
Opening of the Emergency Exit Doors from the Outside
TASK 52-22-00-410-001-A
Closing of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-410-002-A
Closing of the Emergency Exit Doors from the Outside
TASK 52-22-00-860-003-A
Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder
TASK 52-22-00-860-004-A
Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder
TASK 52-73-00-710-002-B
Operational Test of the Warning System related to the Emergency Exits
TASK 52-73-00-710-002-E
Operational Test of the Warning System Related to the Emergency Exit Doors
3. Job Set-up
Subtask 52-71-00-861-057-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 52-71-00-865-071-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
Subtask 52-71-00-010-066-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at emergency exit door 834, 843, 833 or 844.
   (2) Open the applicable emergency exit door from the outside of the aircraft (Ref. AMM TASK 52-22-00-010-002).
   (3) Obey the special precautions before you start the work on the emergency exit door (Ref. AMM TASK 52-22-00-860-003).
   (4) Close emergency exit door 834, 843, 833 or 844 from the inside of the aircraft (Ref. AMM TASK 52-22-00-410-001).
Subtask 52-71-00-010-073-A ** ON A/C NOT FOR ALL
D. Removal of the Lining Panel
   (1) Remove the applicable lining panel (Ref. AMM TASK 25-23-47-000-013):
     (a) For 19WV1:
     (b) For 19WV2:
     (c) For 21WV1:
     (d) For 21WV2:
   (2) Remove the insulation.
Subtask 52-71-00-010-066-B ** ON A/C NOT FOR ALL
E. Get Access
   (1) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position at emergency exit door 835 or 845.
   (2) Open the applicable emergency exit door from the outside of the aircraft (Ref. AMM TASK 52-22-00-010-002).
   (3) Obey the special precautions before you start the work on the emergency exit door (Ref. AMM TASK 52-22-00-860-003).
   (4) Close emergency exit door 835 or 845 from the inside of the aircraft (Ref. AMM TASK 52-22-00-410-001).
Subtask 52-71-00-010-073-B ** ON A/C NOT FOR ALL
F. Removal of the Lining Panel
   (1) Remove the applicable lining panel (Ref. AMM TASK 25-23-47-000-802):
     (a) For 21WV1:
     (b) For 21WV2:
   (2) Remove the insulation.
4. Procedure
Subtask 52-71-00-820-063-A ** ON A/C NOT FOR ALL
A. Adjustment of the Proximity Switch
WARNING: DO NOT OPEN THE EMERGENCY EXIT DURING THE ADJUSTMENT.
   (1) Make sure that the emergency exit doors are closed.
   (2) Disconnect the electrical connector (1) from the proximity switch (2).
   (3) Connect the 355M03210000 CHECKING TOOL-DOORS or the G55M03210000 CHECKING TOOL - DOORS to the electrical connector of the proximity switch (2).
   (4) Release the lock washer (5) from the nut (4).
   (5) Remove the nut (4).
   (6) Remove and discard the lock washer (5) from the target (3).
   (7) Install the new AIPC 52-22-21-24-430 LOCK WASHER (5), the new AIPC 52-22-21-24-690 LOCK WASHER (5), the new AIPC 52-22-21-09-615 LOCK WASHER (5) or the new AIPC 52-22-21-09-218 LOCK WASHER (5) and the nut (4).
   (8) Turn the target (3) until the NEAR indicator light comes on.
   (9) Make sure that the target (3) does not touch the proximity switch (2).
   (10) Turn the target (3) in the opposite direction until the FAR indicator light comes on.
   (11) From this position, turn the target (3) between 2 and 2.5 turns in the direction of the proximity switch (2).
   (12) Tighten the nut (4).
   (13) Safety the nut (4) with the new lock washer (5).
   (14) Disconnect the
355M03210000 CHECKING TOOL-DOORS or the G55M03210000 CHECKING TOOL - DOORS from the electrical connector (1) of the proximity switch (2).
   (15) Connect the electrical connector (1) to the proximity switch (2).
Subtask 52-71-00-820-063-B ** ON A/C NOT FOR ALL
A. Adjustment of the Proximity Switch
WARNING: DO NOT OPEN THE EMERGENCY EXIT DURING THE ADJUSTMENT.
   (1) Make sure that the emergency exit doors are closed.
   (2) Disconnect the electrical connector (1) from the proximity switch (2).
   (3) Connect the 355M03210000 CHECKING TOOL-DOORS or the G55M03210000 CHECKING TOOL - DOORS to the electrical connector of the proximity switch (2).
   (4) Release the lock washer (5) from the nut (4).
   (5) Remove the nut (4).
   (6) Remove and discard the lock washer (5) from the target (3).
   (7) Install the new AIPC 52-22-21-24-430 LOCK WASHER (5), the new AIPC 52-22-21-24-690 LOCK WASHER (5), the new AIPC 52-22-21-09-615 LOCK WASHER (5) or the new AIPC 52-22-21-09-218 LOCK WASHER (5) and the nut (4).
   (8) Turn the target (3) until the NEAR indicator light comes on.
   (9) Make sure that the target (3) does not touch the proximity switch (2).
   (10) Turn the target (3) in the opposite direction until the FAR indicator light comes on.
   (11) From this position, turn the target (3) 3.5 turns in the direction of the proximity switch (2).
   (12) Tighten the nut (4).
   (13) Safety the nut (4) with the new lock washer (5).
   (14) Disconnect the
355M03210000 CHECKING TOOL-DOORS or the G55M03210000 CHECKING TOOL - DOORS from the electrical connector (1) of the proximity switch (2).
   (15) Connect the electrical connector (1) to the proximity switch (2).
Subtask 52-71-00-865-072-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
Subtask 52-71-00-710-053-A ** ON A/C NOT FOR ALL
C. Operational Test
   (1) Do an operational test of the warning system related to the emergency exit doors (Ref. AMM TASK 52-73-00-710-002).
5. Close-up
Subtask 52-71-00-410-077-A ** ON A/C NOT FOR ALL
A. Installation of the Lining Panel
   (1) Install the insulation.
   (2) Install the removed lining panel (Ref. AMM TASK 25-23-47-400-013):
     (a) For 19WV1:
     (b) For 19WV2:
     (c) For 21WV1:
     (d) For 21WV2:
Subtask 52-71-00-410-069-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Obey the special precautions after the work on the emergency exit door (Ref. AMM TASK 52-22-00-860-004).
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Close emergency exit door 833, 843, 834 or 844 from the outside of the aircraft (Ref. AMM TASK 52-22-00-410-002).
   (4) Remove the access platform(s).
Subtask 52-71-00-410-077-B ** ON A/C NOT FOR ALL
C. Installation of the Lining Panel
   (1) Install the insulation.
   (2) Install the removed lining panel (Ref. AMM TASK 25-23-47-400-802):
     (a) For 21WV1:
     (b) For 21WV2:
Subtask 52-71-00-410-069-B ** ON A/C NOT FOR ALL
D. Close Access
   (1) Obey the special precautions after the work on the emergency exit door (Ref. AMM TASK 52-22-00-860-004).
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) Close emergency exit door 835 or 845 from the outside of the aircraft (Ref. AMM TASK 52-22-00-410-002).
   (4) Remove the access platform(s).
Subtask 52-71-00-862-059-A ** ON A/C NOT FOR ALL
E. De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.02 06:28:29 UTC