Reactivation of the Avionics-Compartment Access Doors
TASK 52-70-00-440-004-A
Reactivation of the Avionics-Compartment Access Doors
1. Reason for the Job
MMEL 52-07-06A
AVIONICS COMPARTMENT ACCESS DOOR INDICATION ON THE DOOR/OXY SD PAGE
2. Job Set-up Information
A. Referenced Information
3. Job Set-up
Subtask 52-70-00-869-053-A
Subtask 52-70-00-810-051-A
[Rev.10 from 2021]
2026.04.02 06:28:27 UTC
Reactivation of the Avionics-Compartment Access Doors
1. Reason for the Job
MMEL 52-07-06A
AVIONICS COMPARTMENT ACCESS DOOR INDICATION ON THE DOOR/OXY SD PAGE
2. Job Set-up Information
A. Referenced Information
| REFERENCE | DESIGNATION |
|---|---|
| TSM 52-41-00-810-801 | Disagree between the ECAM System Display Page Indication and the Closed and Locked Position of the Left Avionics-Compartment Door |
| TSM 52-41-00-810-802 | Disagree between the ECAM System Display Page Indication and the Closed and Locked Position of the Right Avionics-Compartment Door |
| TSM 52-41-00-810-803 | Disagree between the ECAM System Display Page Indication and the Closed and Locked Position of the Forward Avionics-Compartment Door |
| TSM 52-41-00-810-804 | Disagree between the ECAM System Display Page Indication and the Closed and Locked Position of the Aft Avionics-Compartment Door |
Subtask 52-70-00-869-053-A
A. Not Applicable
4. ProcedureSubtask 52-70-00-810-051-A
A. Trouble Shooting Procedure
(1) Do the applicable trouble shooting of the related avionics-compartment access doors TSM 52-41-00-810-801, TSM 52-41-00-810-802, TSM 52-41-00-810-803 and/or TSM 52-41-00-810-804.
(1) Do the applicable trouble shooting of the related avionics-compartment access doors TSM 52-41-00-810-801, TSM 52-41-00-810-802, TSM 52-41-00-810-803 and/or TSM 52-41-00-810-804.