Deactivation of the Door Locking System Selector on the Back Up Panel


TASK 52-51-00-040-008-A
Deactivation of the Door Locking System Selector on the Back Up Panel


Task Summary
Access Test Specific Tools Mhr E/T Nb Men
NONONO0.20.21
1. Reason for the Job
MMEL 52-01-03-34A
OFF FUNCTION OF THE LKG SYS ON THE CKPT DOOR BK UP OVERHEAD PANEL
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
3. Job Set-up
Subtask 52-51-00-860-088-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the aircraft electrical circuits are energized (Ref. AMM TASK 24-41-00-861-002).
   (2) Make sure that access to the cockpit is available.
Subtask 52-51-00-865-075-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUDOORS/PAX/MONG1MQT13
4. Procedure
Subtask 52-51-00-040-059-A
A. Do the deactivation of the back-up control system
NOTE: For maintenance purposes only, the normal and back-up systems can be deactivated when you do the related maintenance procedure.
Subtask 52-51-00-865-089-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
122VUDOORS/PAX/MONG1MQT13
122VUCKPT/OVRD SYS/SPLY4MQS10
5. Close-up
Subtask 52-51-00-860-089-A
A. Put the aircraft back to the serviceable condition.
   (1) Make an entry into the aircraft technical log that the Back Up Control System is deactivated.
   (2) Make sure that the work area is clean and clear of tools and other items.
   (3) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
[Rev.10 from 2021] 2026.04.02 06:28:22 UTC