Removal of Access Door 191MB
TASK 52-42-28-000-801-A
Removal of Access Door 191MB
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-42-28-010-050-A ** ON A/C NOT FOR ALL
Subtask 52-42-28-020-050-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:28:20 UTC
Removal of Access Door 191MB
ZONE: 190
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 190 | BELLY FAIR, AIR CONDITIONING & HYD COMPT |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 52-42-28-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at zone 190.
4. Procedure(1) Put the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position at zone 190.
Subtask 52-42-28-020-050-A ** ON A/C NOT FOR ALL
A. Removal of Access Door 191MB
(1) Open the access door (2).
(2) Remove the nut (14), the washer (15), the screw (5) and the bonding strap (6).
(3) Remove the clamps (7) from the pins (8).
(4) Hold the access door (2) and remove the pins (8).
(5) Remove the access door (2).
(6) If necessary, remove the hinges (9) as follows:
(a) Remove the nuts (10) and (12), the washers (11) and (13) and the screws (3) and (4).
(b) Remove the hinges (9).
(1) Open the access door (2).
(2) Remove the nut (14), the washer (15), the screw (5) and the bonding strap (6).
(3) Remove the clamps (7) from the pins (8).
(4) Hold the access door (2) and remove the pins (8).
(5) Remove the access door (2).
(6) If necessary, remove the hinges (9) as follows:
(a) Remove the nuts (10) and (12), the washers (11) and (13) and the screws (3) and (4).
(b) Remove the hinges (9).
Access Door 191MB