W DOC AIRBUS | AMM A320F

Removal of the Potable Water Service-Door


TASK 52-42-14-000-001-A
Removal of the Potable Water Service-Door


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
192NB
 C. Referenced Information
REFERENCE
DESIGNATION
3. Job Set-up
Subtask 52-42-14-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at zone 192.
   (2) Open the service door 192NB.
4. Procedure
Subtask 52-42-14-020-050-A ** ON A/C NOT FOR ALL
A. Removal of the Potable Water Service Door
   (1) Release the spring (5) from the fitting (2).
   (2) Remove the nuts (3) and the bolts (4).
   (3) Remove the door (1).
Subtask 52-42-14-020-050-B ** ON A/C NOT FOR ALL
A. Removal of the Potable Water Service Door
   (1) Release the spring (5) from the fitting (2).
   (2) Remove the nuts (3), the bolts (4) and the door stopper (6).
   (3) Remove the door (1).
[Rev.10 from 2021] 2026.04.02 06:28:18 UTC