Removal of the External-Power Receptacle Door (121AL)
TASK 52-42-12-000-001-A
Removal of the External-Power Receptacle Door (121AL)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-42-12-010-050-A
Subtask 52-42-12-020-050-B
[Rev.10 from 2021]
2026.04.01 05:51:12 UTC
Removal of the External-Power Receptacle Door (121AL)
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121AL |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 52-42-12-010-050-A
A. Get Access
(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at zone 121.
(2) Open the door 121AL.
4. Procedure(1) Put an ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position at zone 121.
(2) Open the door 121AL.
Subtask 52-42-12-020-050-B
A. Removal of the External-Power Receptacle Door
(1) Remove the cotter pin (3) and discard it.
(2) Hold the spring (14).
(3) Remove the nut (4) and the washer (2).
(4) Remove the screw (10) and the plate (8).
(5) Let the spring (14) hang free.
(6) Remove the bolt (6) and the washer (7).
(7) Move the bonding lead (5).
(8) Remove the sealant from the door hinge (12).
(9) Hold the door (9).
(10) Remove the three bolts (13).
(11) Remove the door (9).
(1) Remove the cotter pin (3) and discard it.
(2) Hold the spring (14).
(3) Remove the nut (4) and the washer (2).
(4) Remove the screw (10) and the plate (8).
(5) Let the spring (14) hang free.
(6) Remove the bolt (6) and the washer (7).
(7) Move the bonding lead (5).
(8) Remove the sealant from the door hinge (12).
(9) Hold the door (9).
(10) Remove the three bolts (13).
(11) Remove the door (9).
External-Power Receptacle Door