Reactivation of the Access Door to Potable Water Filling and Drainage (133AL, 171AL)
TASK 52-42-00-440-804-A
Reactivation of the Access Door to Potable Water Filling and Drainage (133AL, 171AL)
1. Reason for the Job
CDL 52-03
ACCESS DOOR TO POTABLE WATER FILLING AND DRAINAGE 133 AL - 171 AL
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-42-00-010-060-A
Subtask 52-42-00-440-056-A
Subtask 52-42-00-410-058-A
[Rev.10 from 2021]
2026.04.02 06:28:17 UTC
Reactivation of the Access Door to Potable Water Filling and Drainage (133AL, 171AL)
1. Reason for the Job
CDL 52-03
ACCESS DOOR TO POTABLE WATER FILLING AND DRAINAGE 133 AL - 171 AL
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 130 | FWD CARGO COMPT AFT BULKHEAD OF AVNCS COMPT TO FWD PRESSURE BULKHEAD OF WING CENTER BOX |
| 170 | AFT CAB U/FLOOR COMPT AFT BHD OF BULK |
| 133AL, 171AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-42-13-400-001-A | Installation of the Service Door |
| TASK 52-42-19-400-801-A | Installation of the Potable Water Service-Door |
Subtask 52-42-00-010-060-A
A. Get Access
(1) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position below the applicable access door.
4. Procedure(1) Put the ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE in position below the applicable access door.
Subtask 52-42-00-440-056-A
A. Reactivation of the Access Door to Potable Water Filling and Drainage (133AL, 171AL)
(1) Remove the high-speed tape from the cutout of the access door.
(2) For access door 171AL, do the steps that follow:
(a) Remove the high-speed tape from the pins (2).
(b) Remove the pins (2) from limit switch 5MA (1).
(3) Install a serviceable access door:
5. Close-up(1) Remove the high-speed tape from the cutout of the access door.
(2) For access door 171AL, do the steps that follow:
(a) Remove the high-speed tape from the pins (2).
(b) Remove the pins (2) from limit switch 5MA (1).
(3) Install a serviceable access door:
Subtask 52-42-00-410-058-A
Access Door to Potable Water Filling and Drainage 133AL