W DOC AIRBUS | AMM A320F

Reactivation of the External-Power Receptacle Door 121AL


TASK 52-42-00-440-003-A
Reactivation of the External-Power Receptacle Door 121AL


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 120
1. Reason for the Job
CDL 52-07
EXTERNAL POWER GROUND CONNECTION ACCESS DOOR ASSY 121 AL
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 1M(3 FT)
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.05RAB9)
Adhesive Film Tape-- Aluminium Foil -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
120
AVIONICS COMPARTMENT
121AL
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 52-42-12-400-001-A
Installation of the External-Power Receptacle Door (121AL)
3. Job Set-up
Subtask 52-42-00-010-051-A
A. Get Access
   (1) Put the ACCESS PLATFORM 1M(3 FT) in position.
4. Procedure
Subtask 52-42-00-440-053-A
A. Reactivation of the External-Power Receptacle Door 121AL
   (1) Remove and discard the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) from the cutout of the fuselage.
   (2) Install a serviceable external-power receptacle door 121AL (Ref. AMM TASK 52-42-12-400-001).
5. Close-up
Subtask 52-42-00-410-054-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close external-power receptacle door 121AL.
   (3) Remove the access platform(s).