Reactivation of the External-Power Receptacle Door 121AL
TASK 52-42-00-440-003-A
Reactivation of the External-Power Receptacle Door 121AL
CDL 52-07
EXTERNAL POWER GROUND CONNECTION ACCESS DOOR ASSY 121 AL
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 52-42-00-010-051-A
Subtask 52-42-00-440-053-A
Subtask 52-42-00-410-054-A
[Rev.10 from 2021]
2026.04.02 06:28:17 UTC
Reactivation of the External-Power Receptacle Door 121AL
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 120
1. Reason for the JobCDL 52-07
EXTERNAL POWER GROUND CONNECTION ACCESS DOOR ASSY 121 AL
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 1M(3 FT) |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.05RAB9) | Adhesive Film Tape-- Aluminium Foil - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 121AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-42-12-400-001-A | Installation of the External-Power Receptacle Door (121AL) |
Subtask 52-42-00-010-051-A
A. Get Access
(1) Put the ACCESS PLATFORM 1M(3 FT) in position.
4. Procedure(1) Put the ACCESS PLATFORM 1M(3 FT) in position.
Subtask 52-42-00-440-053-A
A. Reactivation of the External-Power Receptacle Door 121AL
(1) Remove and discard the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) from the cutout of the fuselage.
(2) Install a serviceable external-power receptacle door 121AL (Ref. AMM TASK 52-42-12-400-001).
5. Close-up(1) Remove and discard the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) from the cutout of the fuselage.
(2) Install a serviceable external-power receptacle door 121AL (Ref. AMM TASK 52-42-12-400-001).
Subtask 52-42-00-410-054-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close external-power receptacle door 121AL.
(3) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close external-power receptacle door 121AL.
(3) Remove the access platform(s).
External-Power Receptacle Door 121AL