Reactivation of Fuel Panel Access-Door 192MB
TASK 52-42-00-440-001-A
Reactivation of Fuel Panel Access-Door 192MB
CDL 28-02
Refuel Panel Door
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-42-00-941-056-A Subtask 52-42-00-865-064-A
Subtask 52-42-00-440-057-A
Subtask 52-42-00-865-065-A
[Rev.10 from 2021]
2026.04.02 06:28:17 UTC
Reactivation of Fuel Panel Access-Door 192MB
ZONE: 190
1. Reason for the JobCDL 28-02
Refuel Panel Door
NOTE: This task is not applicable if fuel panel access-door 192MB is not installed.
2. Job Set-up InformationA. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| No specific | 1 | STEPLADDER 0.5 M (1.6 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 190 | BELLY FAIR, AIR CONDITIONING & HYD COMPT |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-42-18-400-001-A | Installation of the Fuel Panel Access-Door |
Subtask 52-42-00-941-056-A Subtask 52-42-00-865-064-A
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L24 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L23 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L23 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L22 |
Subtask 52-42-00-440-057-A
A. Reactivation of Fuel Panel Access-Door 192MB
(1) Remove the high-speed tape from the cutout of the right belly fairing area near FR37.
(2) Cut and remove the tie-wraps from the temporarily attached connectors.
(3) Remove the CAP-BLANKING from each electrical connector and receptacle.
(4) Connect connector [20QUA] (1) to microswitch [20QU] (2).
(5) Install replacement fuel panel access-door 192MB on the belly fairing (Ref. AMM TASK 52-42-18-400-001).
(6) Attach the spring strut at the attachment fitting of the belly fairing structure.
5. Close-up(1) Remove the high-speed tape from the cutout of the right belly fairing area near FR37.
(2) Cut and remove the tie-wraps from the temporarily attached connectors.
(3) Remove the CAP-BLANKING from each electrical connector and receptacle.
(4) Connect connector [20QUA] (1) to microswitch [20QU] (2).
(5) Install replacement fuel panel access-door 192MB on the belly fairing (Ref. AMM TASK 52-42-18-400-001).
(6) Attach the spring strut at the attachment fitting of the belly fairing structure.
Subtask 52-42-00-865-065-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 52-42-00-410-062-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L24 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L23 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | FUEL/RFL/DFL/SPLY | 2QU | L23 |
| 121VU | FUEL/RFL/DFL/XFR/DEFUEL/VALVE | 1QU | L22 |
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close fuel panel access-door 192MB.
(3) Remove the STEPLADDER 0.5 M (1.6 FT).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Close fuel panel access-door 192MB.
(3) Remove the STEPLADDER 0.5 M (1.6 FT).
Fuel Panel Access-Door 192MB