W DOC AIRBUS | AMM A320F

Reactivation of Fuel Panel Access-Door 192MB


TASK 52-42-00-440-001-A
Reactivation of Fuel Panel Access-Door 192MB


ZONE: 190
1. Reason for the Job
CDL 28-02
Refuel Panel Door
NOTE: This task is not applicable if fuel panel access-door 192MB is not installed.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
STEPLADDER 0.5 M (1.6 FT)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
190
BELLY FAIR, AIR CONDITIONING & HYD COMPT
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 52-42-18-400-001-A
Installation of the Fuel Panel Access-Door
3. Job Set-up
Subtask 52-42-00-941-056-A
A. Get Access
   (1) Put the STEPLADDER 0.5 M (1.6 FT) in position below fuel panel access-door 192MB.
Subtask 52-42-00-865-064-A
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUFUEL/RFL/DFL/SPLY2QUL24
121VUFUEL/RFL/DFL/XFR/DEFUEL/VALVE1QUL23
** ON A/C NOT FOR ALL
121VUFUEL/RFL/DFL/SPLY2QUL23
121VUFUEL/RFL/DFL/XFR/DEFUEL/VALVE1QUL22
4. Procedure
Subtask 52-42-00-440-057-A
A. Reactivation of Fuel Panel Access-Door 192MB
   (1) Remove the high-speed tape from the cutout of the right belly fairing area near FR37.
   (2) Cut and remove the tie-wraps from the temporarily attached connectors.
   (3) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (4) Connect connector [20QUA] (1) to microswitch [20QU] (2).
   (5) Install replacement fuel panel access-door 192MB on the belly fairing (Ref. AMM TASK 52-42-18-400-001).
   (6) Attach the spring strut at the attachment fitting of the belly fairing structure.
5. Close-up
Subtask 52-42-00-865-065-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUFUEL/RFL/DFL/SPLY2QUL24
121VUFUEL/RFL/DFL/XFR/DEFUEL/VALVE1QUL23
** ON A/C NOT FOR ALL
121VUFUEL/RFL/DFL/SPLY2QUL23
121VUFUEL/RFL/DFL/XFR/DEFUEL/VALVE1QUL22
Subtask 52-42-00-410-062-A
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close fuel panel access-door 192MB.
   (3) Remove the STEPLADDER 0.5 M (1.6 FT).
[Rev.10 from 2021] 2026.04.02 06:28:17 UTC