Removal of Access Door 314AR
TASK 52-41-23-000-001-A
Removal of Access Door 314AR
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-41-23-860-050-A
Subtask 52-41-23-020-050-A
[Rev.10 from 2021]
2026.04.02 06:28:16 UTC
Removal of Access Door 314AR
WARNING:
DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
ZONE: 310
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 310 | FUSLG TAIL SECTION AFT OF AFT PRESS BHD |
| 314AR |
| REFERENCE | DESIGNATION |
|---|---|
Subtask 52-41-23-860-050-A
A. Aircraft Maintenance Configuration
(1) Put the WARNING NOTICE(S) in position in the flight compartment to tell persons not to start the APU.
(2) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position below access door 314AR.
4. Procedure(1) Put the WARNING NOTICE(S) in position in the flight compartment to tell persons not to start the APU.
(2) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position below access door 314AR.
Subtask 52-41-23-020-050-A
A. Removal of Access Door 314AR
(1) Loosen the studs (6) and carefully open the access door (5).
(2) Remove the nut (7), the bolt (11) and the washer (10).
(3) Disconnect the bonding strap (9) from the bonding angle (8).
(4) Hold the access door (5) and remove the screws (1) and the washers (2).
(5) Remove the retainer (3), the seal (4) and the access door (5) from the fuselage hinge (12).
(1) Loosen the studs (6) and carefully open the access door (5).
(2) Remove the nut (7), the bolt (11) and the washer (10).
(3) Disconnect the bonding strap (9) from the bonding angle (8).
(4) Hold the access door (5) and remove the screws (1) and the washers (2).
(5) Remove the retainer (3), the seal (4) and the access door (5) from the fuselage hinge (12).
Access Door 314AR