W DOC AIRBUS | AMM A320F

Removal of Access Door 314AR


TASK 52-41-23-000-001-A
Removal of Access Door 314AR


WARNING: DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
ZONE: 310
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
310
FUSLG TAIL SECTION AFT OF AFT PRESS BHD
314AR
 C. Referenced Information
REFERENCE
DESIGNATION
F Access Door 314AR ** ON A/C NOT FOR ALL
F Access Door 314AR ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 52-41-23-860-050-A
A. Aircraft Maintenance Configuration
   (1) Put the WARNING NOTICE(S) in position in the flight compartment to tell persons not to start the APU.
   (2) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position below access door 314AR.
4. Procedure
Subtask 52-41-23-020-050-A
A. Removal of Access Door 314AR
   (1) Loosen the studs (6) and carefully open the access door (5).
   (2) Remove the nut (7), the bolt (11) and the washer (10).
   (3) Disconnect the bonding strap (9) from the bonding angle (8).
   (4) Hold the access door (5) and remove the screws (1) and the washers (2).
   (5) Remove the retainer (3), the seal (4) and the access door (5) from the fuselage hinge (12).
[Rev.10 from 2021] 2026.04.02 06:28:16 UTC