Installation of the Seal of the Forward Avionics-Compartment Door
TASK 52-41-11-400-003-A
Installation of the Seal of the Forward Avionics-Compartment Door
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-41-11-860-053-A
Subtask 52-41-11-420-053-A
Subtask 52-41-11-410-054-A
[Rev.10 from 2021]
2026.04.02 07:23:41 UTC
Installation of the Seal of the Forward Avionics-Compartment Door
WARNING:
PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
- THE FLIGHT CONTROLS
- THE FLIGHT CONTROL SURFACES
- THE LANDING GEAR AND THE RELATED DOORS
- COMPONENTS THAT MOVE.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 811 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-41-11-000-001-A | Removal of the Avionics-Compartment Forward Door |
| TASK 52-41-11-400-001-A | Installation of the Avionics-Compartment Forward Door |
Subtask 52-41-11-860-053-A
A. Aircraft Maintenance Configuration
(1) Make sure that an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at zone 120.
(2) Make sure that the forward avionics-compartment door 811 is removed (Ref. AMM TASK 52-41-11-000-001).
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
4. Procedure(1) Make sure that an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at zone 120.
(2) Make sure that the forward avionics-compartment door 811 is removed (Ref. AMM TASK 52-41-11-000-001).
(3) Make sure that the parts retained from the removed component are clean and in the correct condition.
Subtask 52-41-11-420-053-A
A. Installation of the Seal
(1) Put the seal (2) in position around the door (1).
(2) Put the seal-retainers (3) in position. Make sure that the groove of the seal (2) is between the seal-retainers (3) and the door (1).
(5) Slowly tighten the screws (4). Make sure that the pressure of the seal-retainers (3) stays regular.
5. Close-up(1) Put the seal (2) in position around the door (1).
(2) Put the seal-retainers (3) in position. Make sure that the groove of the seal (2) is between the seal-retainers (3) and the door (1).
NOTE: Refer to the marks made during the removal procedure to install the seal-retainers (3) in the correct position.
(3) Install the 24 washers (5) and the 24 screws (4). NOTE: Do not fully tighten them at this time.
(4) Do a visual check of the seal (2) position. (5) Slowly tighten the screws (4). Make sure that the pressure of the seal-retainers (3) stays regular.
Subtask 52-41-11-410-054-A
A. Close Access
(1) Install the forward avionics-compartment door 811 (Ref. AMM TASK 52-41-11-400-001).
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(3) Remove the access platform(s).
(1) Install the forward avionics-compartment door 811 (Ref. AMM TASK 52-41-11-400-001).
(2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(3) Remove the access platform(s).
Seal of the Forward Avionics-Compartment Door