Reactivation of the Access Door of the Blue Hydraulic System
TASK 52-41-00-440-001-A
Reactivation of the Access Door of the Blue Hydraulic System
CDL 52-21
Blue Hydraulic Access Door 197 FB
(Old CDL reference: 52-17)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-41-00-941-052-A 4. Procedure
Subtask 52-41-00-440-050-A
Subtask 52-41-00-410-057-A
[Rev.10 from 2021]
2026.04.02 06:28:13 UTC
Reactivation of the Access Door of the Blue Hydraulic System
ZONE: 190
1. Reason for the JobCDL 52-21
Blue Hydraulic Access Door 197 FB
(Old CDL reference: 52-17)
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 190 | BELLY FAIR, AIR CONDITIONING & HYD COMPT |
| 197FB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-41-24-400-001-A | Installation of the Access Door (197FB) of the Blue Hydraulic System |
Subtask 52-41-00-941-052-A 4. Procedure
Subtask 52-41-00-440-050-A
A. Reactivation of the Access Door
(1) Remove the high-speed tape from the cutout of the belly fairing panel.
(2) Remove the temporarily attached support link from the belly fairing structure.
(3) Install a serviceable access door 197FB on the belly fairing panel (Ref. AMM TASK 52-41-24-400-001).
5. Close-up(1) Remove the high-speed tape from the cutout of the belly fairing panel.
(2) Remove the temporarily attached support link from the belly fairing structure.
(3) Install a serviceable access door 197FB on the belly fairing panel (Ref. AMM TASK 52-41-24-400-001).
Subtask 52-41-00-410-057-A
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Make sure that access door 197FB is closed.
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Make sure that access door 197FB is closed.
(3) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Access Door of the Blue Hydraulic System