Detailed Inspection of the Door Seals.
TASK 52-41-00-210-001-A
Detailed Inspection of the Door Seals.
1. Reason for the Job
Refer to the MPD TASK: 524100-01
DETAILED INSPECTION OF DOOR SEALS
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-41-00-010-050-A
Subtask 52-41-00-220-050-A
Subtask 52-41-00-865-051-A
[Rev.10 from 2021]
2026.04.02 06:28:13 UTC
Detailed Inspection of the Door Seals.
1. Reason for the Job
Refer to the MPD TASK: 524100-01
DETAILED INSPECTION OF DOOR SEALS
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 811 | FORWARD AVIONICS COMPARTMENT DOOR |
| 812 | LATERAL AVIONICS COMPARTMENT DOOR (LEFT) |
| 822 | LATERAL AVIONICS COMPT DOOR (RIGHT) |
| 824 | REAR AVIONIC COMPARTMENT DOOR (RIGHT) |
| 811, 812, 822, 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
Subtask 52-41-00-010-050-A
A. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) in position at zone 811, 812, 822 or 824.
(2) Open the applicable access door 811, 812, 822 or 824 (Ref. AMM TASK 52-41-00-010-002).
Subtask 52-41-00-865-050-A (1) Put an ACCESS PLATFORM 2M (6 FT) in position at zone 811, 812, 822 or 824.
(2) Open the applicable access door 811, 812, 822 or 824 (Ref. AMM TASK 52-41-00-010-002).
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/AVNCS | 46WV | P02 |
Subtask 52-41-00-220-050-A
A. Inspection
(1) Do a detailed inspection of the door seals.
(2) Make sure that there are no signs of chafing and breaks.
5. Close-up(1) Do a detailed inspection of the door seals.
(2) Make sure that there are no signs of chafing and breaks.
Subtask 52-41-00-865-051-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 52-41-00-410-050-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/AVNCS | 46WV | P02 |
B. Close Access
(1) Close the applicable access door 811, 812, 822 or 824 (Ref. AMM TASK 52-41-00-410-002).
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the access platform(s).
(1) Close the applicable access door 811, 812, 822 or 824 (Ref. AMM TASK 52-41-00-410-002).
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Remove the access platform(s).