Removal of the Electro-Manual Selector Valve
TASK 52-36-12-000-001-A
Removal of the Electro-Manual Selector Valve
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-36-12-010-050-A
Subtask 52-36-12-020-050-A
[Rev.10 from 2021]
2026.04.02 06:28:11 UTC
Removal of the Electro-Manual Selector Valve
WARNING:
MAKE SURE THAT THE TRAVEL RANGES OF THE FLIGHT CONTROLS SURFACES ARE CLEAR. MOVEMENT OF FLIGHT CONTROLS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
WARNING:
MAKE SURE THAT THE GROUND SAFETY-LOCKS ARE IN POSITION ON THE LANDING GEAR. THIS WILL PREVENT UNWANTED MOVEMENT OF THE LANDING GEAR, AND THUS POSSIBLE INJURY TO PERSONS AND DAMAGE TO THE AIRCRAFT AND/OR EQUIPMENT.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | AR | CONTAINER - HYDRAULIC FLUID RESISTANT |
| No specific | AR | PLUG - BLANKING |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 198 | REAR FAIRING |
| 198CB |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 20-23-21-911-001-A | Removal/Installation of the Bobbins from their Housings and Installation of O-rings, Square Seals, and Back-up Rings on the Bobbins |
| TASK 29-00-00-864-001-A | Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action |
| TASK 29-00-00-910-002-A | Safety Procedures of the Hydraulic System |
| TASK 29-14-00-614-001-A | Depressurization of the Hydraulic Reservoirs |
| TASK 29-23-00-860-001-A | Disconnection of the Isolation Coupling of the Power Transfer Unit (PTU) |
Subtask 52-36-12-010-050-A
A. Get Access
(1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position to the RH aft belly fairing area.
(2) Open the access door 198CB of the Yellow ground service panel.
(3) Make sure that the FWD and AFT Cargo Compartment Doors (referred to as cargo door) are closed.
Subtask 52-36-12-865-050-A (1) Put an ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE in position to the RH aft belly fairing area.
(2) Open the access door 198CB of the Yellow ground service panel.
(3) Make sure that the FWD and AFT Cargo Compartment Doors (referred to as cargo door) are closed.
B. Open, safety and tag this(these) circuit breaker(s):
Subtask 52-36-12-860-052-A | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N30 |
| ** ON A/C NOT FOR ALL | |||
| 121VU | HYDRAULIC/HYD POWER/Y | 3803GX | N31 |
| ** ON A/C ALL | |||
| 122VU | DOORS/CARGO | 1MJ | T12 |
| 123VU | Y HYD/ELEC/PUMP | 3802GX | AB06 |
| 123VU | Y HYD/ELEC/ELEC PUMP/NORM | 3801GX | AB03 |
C. Aircraft Maintenance Configuration
(2) Make sure that the Yellow hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-00-00-864-001).
(3) Depressurize the reservoir of the Yellow hydraulic system (Ref. AMM TASK 29-14-00-614-001).
(4) Disconnect the isolation coupling of the Power Transfer Unit (PTU) (Ref. AMM TASK 29-23-00-860-001).
(5) Put the warning notices in position to tell persons not to pressurize the Yellow hydraulic system:
4. ProcedureWARNING:
OBEY THE HYDRAULIC SAFETY PROCEDURES.
(1) Obey the hydraulic safety procedures (Ref. AMM TASK 29-00-00-910-002). (2) Make sure that the Yellow hydraulic system is depressurized and put it in the maintenance configuration.
(Ref. AMM TASK 29-00-00-864-001).
(3) Depressurize the reservoir of the Yellow hydraulic system (Ref. AMM TASK 29-14-00-614-001).
(4) Disconnect the isolation coupling of the Power Transfer Unit (PTU) (Ref. AMM TASK 29-23-00-860-001).
(5) Put the warning notices in position to tell persons not to pressurize the Yellow hydraulic system:
- In the cockpit on the hydraulic section 40VU of the overhead panel,
- On the ground service panel of the Yellow hydraulic system.
Subtask 52-36-12-020-050-A
A. Removal of the Electro-Manual Selector Valve
(1) Remove the bolts (9) and (10) and the washers (8) and (11).
(2) Remove the bonding strap (12) from the selector valve (7).
(3) Remove the selector valve (7) from the valve panel (1).
(4) Remove the bobbins (4) and (17) from the valve panel (1) or the selector valve (7) (Ref. AMM TASK 20-23-21-911-001).
(5) Install PLUG - BLANKING in the open ports.
(6) Remove and discard the O-ring (14) from the electrical connector (13).
(7) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
(1) Remove the bolts (9) and (10) and the washers (8) and (11).
(2) Remove the bonding strap (12) from the selector valve (7).
(3) Remove the selector valve (7) from the valve panel (1).
(4) Remove the bobbins (4) and (17) from the valve panel (1) or the selector valve (7) (Ref. AMM TASK 20-23-21-911-001).
(5) Install PLUG - BLANKING in the open ports.
(6) Remove and discard the O-ring (14) from the electrical connector (13).
(7) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
Electro-Manual Selector Valve