Operational Check of Door Closing Inhibition by Door Sill Latch Switch
TASK 52-35-00-710-001-A
Operational Check of Door Closing Inhibition by Door Sill Latch Switch
Refer to the MPD TASK: 523500-01
OPERATIONAL CHECK OF DOOR CLOSING INHIBITION BY DOOR SILL LATCH SWITCH
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 52-35-00-010-050-A ** ON A/C NOT FOR ALL
Subtask 52-35-00-710-050-A ** ON A/C NOT FOR ALL
Subtask 52-35-00-410-053-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:28:09 UTC
Operational Check of Door Closing Inhibition by Door Sill Latch Switch
CAUTION:
IMMEDIATELY AFTER YOU OPEN THE CARGO COMPARTMENT DOOR, RECORD ON THE WORK CARD ON THE DOOR, THE DATE AND TIME WHEN YOU OPENED IT. IF THE CARGO COMPARTMENT DOOR STAYS OPEN FOR 12 HOURS OR MORE, YOU MUST BLEED THE HYDRAULIC SYSTEM RELATED TO IT. IF YOU DO NOT OBEY THESE PRECAUTIONS, THE DOOR CAN CLOSE SUDDENLY WHEN YOU SET THE DOOR TO "CLOSE". THIS CAN CAUSE DAMAGE TO THE DOOR AND TO THE AIRCRAFT STRUCTURE.
1. Reason for the JobRefer to the MPD TASK: 523500-01
OPERATIONAL CHECK OF DOOR CLOSING INHIBITION BY DOOR SILL LATCH SWITCH
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 825 | FORWARD CARGO COMPARTMENT DOOR |
| 826 | AFT CARGO COMPARTMENT DOOR |
| 134AR, 154AR |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
| TASK 52-30-00-860-002-A | Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 52-35-00-010-050-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Open the access door 134AR or 154AR to get access to the selector of the control panel.
(2) Open the FWD and/or AFT cargo-compartment door(s) (referred to as cargo door(s)) (Ref. AMM TASK 52-30-00-860-001).
(3) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position to the cargo door.
4. Procedure(1) Open the access door 134AR or 154AR to get access to the selector of the control panel.
(2) Open the FWD and/or AFT cargo-compartment door(s) (referred to as cargo door(s)) (Ref. AMM TASK 52-30-00-860-001).
(3) Put the ACCESS PLATFORM 3M (10 FT)- ADJUSTABLE in position to the cargo door.
Subtask 52-35-00-710-050-A ** ON A/C NOT FOR ALL
A. Operational Check of FWD and AFT Door Closing Inhibition by Door Sill Latch Switch
(1) Do this check to make sure that the microswitches of the door sill latches prevent the door from closing.
5. Close-up(1) Do this check to make sure that the microswitches of the door sill latches prevent the door from closing.
NOTE: If the check does not show the correct results, stop it immediately and repair the applicable parts.
| ACTION | RESULT |
|---|---|
| 1.In the door sill area: | In the door sill area: |
|
|
| 2.On the control panel: | |
|
|
| 3.On the control panel: | On the control panel: |
|
|
| 4.In the door sill area: | In the door sill area: |
|
|
| 5.On the control panel: | |
|
|
| 6.On the control panel: | On the control panel: |
|
|
| 7.In the door sill area: | In the door sill area: |
|
|
| 8.On the control panel: | |
|
|
| 9.On the control panel: | On the control panel: |
|
|
| 10.In the door sill area: | In the door sill area: |
|
|
| 11.On the control panel: | |
|
|
Subtask 52-35-00-410-053-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the FWD or AFT cargo-compartment door(s) is (are) correctly closed (Ref. AMM TASK 52-30-00-860-002).
(2) Close the access door 134AR or 154AR.
(3) Remove the access platform(s).
(1) Make sure that the FWD or AFT cargo-compartment door(s) is (are) correctly closed (Ref. AMM TASK 52-30-00-860-002).
(2) Close the access door 134AR or 154AR.
(3) Remove the access platform(s).