Removal of the Lock Fitting Components
TASK 52-32-32-000-001-A
Removal of the Lock Fitting Components
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Referenced Information
3. Job Set-up
Subtask 52-32-32-010-050-A
Subtask 52-32-32-020-050-A
[Rev.10 from 2021]
2026.04.02 06:28:04 UTC
Removal of the Lock Fitting Components
CAUTION:
IMMEDIATELY AFTER YOU OPEN THE CARGO COMPARTMENT DOOR, RECORD ON THE WORK CARD ON THE DOOR, THE DATE AND TIME WHEN YOU OPENED IT. IF THE CARGO COMPARTMENT DOOR STAYS OPEN FOR 12 HOURS OR MORE, YOU MUST BLEED THE HYDRAULIC SYSTEM RELATED TO IT. IF YOU DO NOT OBEY THESE PRECAUTIONS, THE DOOR CAN CLOSE SUDDENLY WHEN YOU SET THE DOOR TO "CLOSE". THIS CAN CAUSE DAMAGE TO THE DOOR AND TO THE AIRCRAFT STRUCTURE.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | SAFETY CLIP - CIRCUIT BREAKER |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-30-00-860-001-A | Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump |
Subtask 52-32-32-010-050-A
A. Get Access
(1) Put the ACCESS PLATFORM 2M (6 FT) in position below the closed AFT cargo compartment door (referred to as cargo door).
(2) Open the AFT cargo door and safety it with the actuator safety locks (Ref. AMM TASK 52-30-00-860-001).
Subtask 52-32-32-865-050-A (1) Put the ACCESS PLATFORM 2M (6 FT) in position below the closed AFT cargo compartment door (referred to as cargo door).
(2) Open the AFT cargo door and safety it with the actuator safety locks (Ref. AMM TASK 52-30-00-860-001).
B. Open, safety and tag this(these) circuit breaker(s):
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C ALL | |||
| 122VU | DOORS/CARGO | 1MJ | T12 |
Subtask 52-32-32-020-050-A
A. Removal of the Lock Fitting Components
(1) Make a color mark on the subsequent components to find easier their correct installation position:
(3) Remove the nut (2) and the washer (3) from the eccentric bolt (9).
(4) Remove the nuts (10) and the washers (11) from the special bolts (12) of the door frame fitting (13).
(5) Remove the serrated plate (4) from the adjusting bush (5).
(6) Hold the roll (7) and remove the eccentric bolt (9) together with the serrated plate (8) from the door frame fitting (13).
(7) Disengage the serrated plate (8) from the eccentric bolt (9).
(8) Remove the eccentric bush (6) from the roll (7).
(9) Remove the adjusting bush (5) from the door frame fitting (13).
(1) Make a color mark on the subsequent components to find easier their correct installation position:
- the serrated plate (4) and the adjusting bush (5),
- the serrated plate (8) and the eccentric bolt (9).
NOTE: This procedure is not necessary when the center punches of these components are aligned.
(2) Remove and discard the cotter pin (1) from the nut (2). (3) Remove the nut (2) and the washer (3) from the eccentric bolt (9).
(4) Remove the nuts (10) and the washers (11) from the special bolts (12) of the door frame fitting (13).
(5) Remove the serrated plate (4) from the adjusting bush (5).
(6) Hold the roll (7) and remove the eccentric bolt (9) together with the serrated plate (8) from the door frame fitting (13).
(7) Disengage the serrated plate (8) from the eccentric bolt (9).
(8) Remove the eccentric bush (6) from the roll (7).
(9) Remove the adjusting bush (5) from the door frame fitting (13).
Lock Fitting Components