W DOC AIRBUS | AMM A320F

Installation of the Wiring Harness


TASK 52-32-24-400-001-A
Installation of the Wiring Harness


CAUTION: IMMEDIATELY AFTER YOU OPEN THE CARGO COMPARTMENT DOOR, RECORD ON THE WORK CARD ON THE DOOR, THE DATE AND TIME WHEN YOU OPENED IT. IF THE CARGO COMPARTMENT DOOR STAYS OPEN FOR 12 HOURS OR MORE, YOU MUST BLEED THE HYDRAULIC SYSTEM RELATED TO IT. IF YOU DO NOT OBEY THESE PRECAUTIONS, THE DOOR CAN CLOSE SUDDENLY WHEN YOU SET THE DOOR TO "CLOSE". THIS CAN CAUSE DAMAGE TO THE DOOR AND TO THE AIRCRAFT STRUCTURE.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
98D52307515000
1
SAFETY LOCK-ACTUATOR,CARGO DOORS
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 52-30-00-860-001-A
Open the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-30-00-860-002-A
Close the FWD or Aft Cargo-Compartment Door with the Yellow Electric Pump
TASK 52-32-13-400-001-A
Installation of the Lining and Insulation
3. Job Set-up
Subtask 52-32-24-860-050-A
A. Aircraft Maintenance Configuration
   (1) Make sure that the cargo door is opened (Ref. AMM TASK 52-30-00-860-001) and safetied with the 98D52307515000 SAFETY LOCK-ACTUATOR,CARGO DOORS.
   (2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below the opened cargo door.
Subtask 52-32-24-865-051-A
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN30
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN31
** ON A/C ALL
122VUDOORS/CARGO1MJT12
123VUY HYD/ELEC/PUMP3802GXAB06
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
4. Procedure
Subtask 52-32-24-420-050-B
A. Installation of the Wiring Harness 4613VB
   (1) Make sure that the parts retained from the removed component are clean and in the correct condition.
   (2) Do an inspection of the component interfaces and the adjacent area.
   (3) If removed, assemble the clamps (4), (8) and (16) together with the sleeves (7) and (13) on the wiring harness (1).
   (4) Do an inspection of the component interfaces and the adjacent area.
   (5) Put the clamp (4) in position to the door angle (2) and attach it with the bolt (5) and the nut (3).
   (6) Connect the electrical wires of the wiring harness (1) to the termial block (6) as follows:
--------------------------- ----------------------------
! WIRE NO ! TERMINAL NO ! ! WIRE NO ! TERMINAL NO !
--------------------------- ----------------------------
! 2552-1105 ! 4K ! ! 2552-1112 ! 3H !
! 2552-1106 ! 4J ! ! 2552-1113 ! 3G !
! 2552-1107 ! 4H ! ! 2552-1114 ! 3F !
! 2552-1108 ! 4G ! ! 3154-5862B ! 2G !
! 2552-1109 ! 4F ! ! 3152-5862R ! 2A !
! 2552-1110 ! 3E ! ! 5235-1010B ! 1G !
! 2552-1111 ! 3J ! ! 5235-1010R ! 1A !

   (7) Put the clamp (8) to the actuator fitting bracket (10) and attach it with the bolt (9) and the washer (11) and the nut (12).
   (8) Measure a distance of 590.0 mm (23.2284 in.) from the door lining to set the clamp (16) in its installation position.
   (9) Put the clamp (16) in position to the bolt (17) of the fitting (18) and attach it with the washer (15) and the nut (14).
   (10) Put the spacer (20), the clamp (21), the spacer (22) and the clamp (25) in position to the ceiling lining (19).
   (11) Install the screw (23) and the washer (24) on the ceiling panel (19).
   (12) Remove the CAP-BLANKING from each electrical connector and receptacle.
   (13) Make sure that all the electrical connections are clean and in the correct condition.
   (14) Connect the electrical connector (29) to the receptacle (28).
   (15) Put the wiring harness (1) in position to the cable clamps (27) and attach it with the tie-raps (26).
Subtask 52-32-24-820-050-A
B. Adjustment Procedure
   (1) Measure the distance "X" between the lining and the wiring harness (1).
NOTE: The distance "X" must be less 70.0 mm (2.7559 in.).
   (2) If the distance "X" is more than allowed, loosen the clamp (16) and move the wiring harness (1) inboard as required.
   (3) Close and open the cargo door (Ref. AMM TASK 52-30-00-860-001) and (Ref. AMM TASK 52-30-00-860-002).
   (4) Make sure that the distance "X" is correct.
5. Close-up
Subtask 52-32-24-865-052-A
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN30
** ON A/C NOT FOR ALL
121VUHYDRAULIC/HYD POWER/Y3803GXN31
** ON A/C ALL
122VUDOORS/CARGO1MJT12
123VUY HYD/ELEC/PUMP3802GXAB06
123VUY HYD/ELEC/ELEC PUMP/NORM3801GXAB03
Subtask 52-32-24-410-050-A
B. Close Access
   (1) Install the removed door lining (Ref. AMM TASK 52-32-13-400-001).
   (2) Remove the access platform(s).
   (3) Close and lock the cargo door correctly (Ref. AMM TASK 52-30-00-860-002).