W DOC AIRBUS | AMM A320F

Reactivation of Cargo Doors


TASK 52-30-00-440-001-A
Reactivation of Cargo Doors


ZONE: 825
ZONE: 826
ZONE: 827
1. Reason for the Job
MMEL 52-30-01B
CARGO DOOR (FWD, AFT AND BULK (IF INSTALLED))
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
825
FORWARD CARGO COMPARTMENT DOOR
826
AFT CARGO COMPARTMENT DOOR
827
BULK CARGO COMPARTMENT DOOR
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TSM 52-31-00-810-801
(for corrective action)
TSM 52-32-00-810-801
(for corrective action)
TSM 52-33-00-810-801
(for corrective action)
3. Job Set-up
Subtask 52-30-00-861-052-A
A. Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
4. Procedure
Subtask 52-30-00-810-050-A ** ON A/C NOT FOR ALL
A. Do the troubleshooting procedure of the FWD and/or AFT cargo-compartment door TSM 52-31-00-810-801 TSM 52-32-00-810-801.
Subtask 52-30-00-810-050-B ** ON A/C NOT FOR ALL
A. Do the troubleshooting procedure of the
5. Close-up
Subtask 52-30-00-862-052-A
A. De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:27:48 UTC