1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
833, 834, 843, 844
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 25-62-00-481-001-A
Special Precautions before Work on the Offwing Escape-Slide Systems
TASK 52-22-00-410-802-A
Closing of the Overwing Emergency-Exit Door from the Passenger Compartment
3. Job Set-up
Subtask 52-22-71-860-065-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Make sure that applicable overwing emergency-door 833 ( 843) or 834 ( 844) is closed, latched and locked (Ref. AMM TASK 52-22-00-410-802).
   (3) Obey the special precautions before you start work on the door (Ref. AMM TASK 25-62-00-481-001).
   (4) On the overhead panel, on the SIGNS section of the control panel 25VU, make sure that:
  • The EMER EXIT LH switch is in the OFF position.
  • The NO PED switch is in the OFF position.
   (5) Put the WARNING NOTICE(S) in position to tell persons not to operate these switches.
   (6) On Flight Attendant Panel (FAP) 120RH, make sure that the EMER button and its light are off.
Subtask 52-22-71-865-062-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VULIGHTING/EMER LT/CABIN2WLH04
49VULIGHTING/EMER LT/CABIN1WLH03
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
122VUFLIGHT LOCK OWD40WNU16
122VULIGHTING/CABIN/EMER/LT3WLV07
Subtask 52-22-71-010-054-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Remove the handle cover (1) from the related overwing emergency-exit door.
4. Procedure
Subtask 52-22-71-020-054-A ** ON A/C NOT FOR ALL
A. Removal of the Handle Proximity Sensor
   (1) Disconnect the electrical connector (3) from the sensor (4).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Remove and discard the lockwire:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
     (a) Remove and discard the lockwire from the locknut (7).
   (4) Remove the locknut (7) with the lockwasher (6).
   (5) Remove the sensor (4) from the bracket (5).
[Rev.10 from 2021] 2026.04.02 06:27:47 UTC