W DOC AIRBUS | AMM A320F

Removal of the Escape-Slide Handle Proximity-Switch


TASK 52-22-71-000-803-A
Removal of the Escape-Slide Handle Proximity-Switch


FIN: 34WN1 ** ON A/C NOT FOR ALL
FIN: 34WN2 ** ON A/C NOT FOR ALL
FIN: 34WN3 ** ON A/C NOT FOR ALL
FIN: 34WN4 ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
833, 834, 843, 844
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 25-23-47-000-803-A
Removal of the Door Lining from the Overwing Emergency Exit
TASK 52-22-00-410-802-A
Closing of the Overwing Emergency-Exit Door from the Passenger Compartment
3. Job Set-up
Subtask 52-22-71-860-067-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Make sure that applicable overwing emergency-exit door 833 ( 843) or 834 ( 844) is closed, latched and locked (Ref. AMM TASK 52-22-00-410-802).
Subtask 52-22-71-865-053-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
122VUFLIGHT LOCK OWD40WNU16
Subtask 52-22-71-010-051-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Remove the lining of the overwing emergency-exit door (Ref. AMM TASK 25-23-47-000-803).
4. Procedure
Subtask 52-22-71-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Escape-Slide Handle Proximity-Switch
   (1) Remove the switch (4):
     (a) Disconnect the electrical connector (5) from the switch (4).
     (b) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
     (c) Remove and discard the lockwire:
WARNING: USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
       1 Remove and discard the lockwire from the locknut (1).
     (d) Remove the locknut (1).
     (e) Remove and discard the lockwasher (2).
     (f) Remove the switch (4) from the bracket (3).
[Rev.10 from 2021] 2026.04.02 06:27:46 UTC