Preventive Seepage Procedure
TASK 52-22-18-300-001-A
Preventive Seepage Procedure
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 52-22-18-010-051-A ** ON A/C NOT FOR ALL
Subtask 52-22-18-390-050-A ** ON A/C NOT FOR ALL
Subtask 52-22-18-410-051-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:27:41 UTC
Preventive Seepage Procedure
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.03FAB1) | Mineral Oil base Grease-- Vaseline or Petrolatum - |
| (Material No.08BPA1) | Non Aqueous Cleaner-Non structural use - - |
| (Material No.14SBA1) | Textile-Lint free Cotton - |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 51-75-12-300-001-A | Repair of Major Paint Damage on Light Alloy and Composite Material |
| TASK 52-22-00-010-001-A | Opening of the Emergency Exit Doors from the Passenger Compartment |
| TASK 52-22-00-410-001-A | Closing of the Emergency Exit Doors from the Passenger Compartment |
| TASK 52-22-00-860-003-A | Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder |
| TASK 52-22-00-860-004-A | Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder |
Subtask 52-22-18-010-051-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Open the applicable emergency exit door (referred to as door) (Ref. AMM TASK 52-22-00-010-001).
(2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the opened door.
(3) Make sure that the special precaution procedure on the door damper and emergency operation cylinder is done (Ref. AMM TASK 52-22-00-860-003).
4. Procedure(1) Open the applicable emergency exit door (referred to as door) (Ref. AMM TASK 52-22-00-010-001).
(2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the opened door.
(3) Make sure that the special precaution procedure on the door damper and emergency operation cylinder is done (Ref. AMM TASK 52-22-00-860-003).
Subtask 52-22-18-390-050-A ** ON A/C NOT FOR ALL
A. Seepage Prevention at the Sealing Profile
Sealing Profile at the Emergency Exit - Seepage Prevention ** ON A/C NOT FOR ALL
Sealing Profile at the Emergency Exit - Seepage Prevention ** ON A/C NOT FOR ALL
(1) Clean the lower area of the sealing profile with Non Aqueous Cleaner-Non structural use - - (Material No.08BPA1) and a Textile-Lint free Cotton - (Material No.14SBA1) .
(2) If necessary, repair the paint layer of the sealing profile (Ref. AMM TASK 51-75-12-300-001).
(3) Apply a layer of Mineral Oil base Grease-- Vaseline or Petrolatum - (Material No.03FAB1) on the area of the sealing profile that touches the door.
5. Close-up
Sealing Profile at the Emergency Exit - Seepage Prevention ** ON A/C NOT FOR ALL
Sealing Profile at the Emergency Exit - Seepage Prevention ** ON A/C NOT FOR ALL (2) If necessary, repair the paint layer of the sealing profile (Ref. AMM TASK 51-75-12-300-001).
(3) Apply a layer of Mineral Oil base Grease-- Vaseline or Petrolatum - (Material No.03FAB1) on the area of the sealing profile that touches the door.
Subtask 52-22-18-410-051-A ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Do the special precaution on the door damper and emergency operation cylinder after maintenance (Ref. AMM TASK 52-22-00-860-004).
(3) Close the door (Ref. AMM TASK 52-22-00-410-001).
(4) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Do the special precaution on the door damper and emergency operation cylinder after maintenance (Ref. AMM TASK 52-22-00-860-004).
(3) Close the door (Ref. AMM TASK 52-22-00-410-001).
(4) Remove the access platform(s).