W DOC AIRBUS | AMM A320F

Removal of the Telescopic Rod Assembly


TASK 52-22-14-000-002-A
Removal of the Telescopic Rod Assembly


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 52-22-00-010-001-A
Opening of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-860-003-A
Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder
F Telescopic Rod Assembly ** ON A/C NOT FOR ALL
F Telescopic Rod Assembly ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 52-22-14-010-051-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Partly open the applicable emergency exit door (referred to as door) as required (Ref. AMM TASK 52-22-00-010-001).
   (2) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the partly opened door.
   (3) Make sure that the special precaution procedure for the door damper and emergency operation cylinder is completed (Ref. AMM TASK 52-22-00-860-003).
4. Procedure
Subtask 52-22-14-020-051-A ** ON A/C NOT FOR ALL
A. Removal of the Telescopic Rod Assembly
   (1) Disconnect the telescopic rod assembly (57) from the yoke assembly (52) as follows:
     (a) Remove and discard the cotter pin (48) from the nut (49).
     (b) Remove the nut (49) and the washer (50) from bolt (54).
     (c) Remove the bolt (54) and the washer (53) from the yoke assembly (52).
     (d) Hold the piston of the door damper (55) and disassemble the fork-end (56) from the yoke assembly (52).
     (e) If neceesary, remove the bush (51) from the yoke assembly (52).
   (2) Disconnect the telescopic rod assembly (57) from the door fitting (35) as follows:
     (a) Remove and discard the cotter pin (41) from the nut (42).
     (b) Remove the nut (42), the washer (43), tab plate (44), the washer (47) and the bolt (46).
NOTE: Remove lock plate (59) if installed as an alternative to the washer (43) and the tab plate (44).
     (c) Hold the telescopic rod assembly (57) and carefully remove the spacer (45) from the sliding sleeve (58).
     (d) Disassemble the sliding sleeve (58) from the transversal link (40).
   (3) If necessary, remove the transveral link (40) from the door fitting (35) as follows:
     (a) Remove and discard the cotter pin (31) from the nut (32).
     (b) Remove the nut (32) and the washer (33) from the transversal link (40).
     (c) Remove the nuts (39), the washers (37) and the bolts (36) from the door fitting (35).
     (d) Hold the transversal link (40) and remove the bearing bracket (38) from the door fitting (35).
     (e) Disassemble the transveral link (40) from the door fitting (35).
     (f) If required, remove the bush (34) from the door fitting (35).
[Rev.10 from 2021] 2026.04.02 06:27:41 UTC