W DOC AIRBUS | AMM A320F

Installation of the Door Buffer


TASK 52-22-12-400-003-A
Installation of the Door Buffer


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.04EAC2)
Primer Polyurethane Paint_- Corrosion Inhibiting Structure
(Material No.04JME4)
Top Coat Polyurethane_- Grey Internal Structure
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 52-22-00-010-001-A
Opening of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-410-001-A
Closing of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-820-006-A
Adjustment of the Door Buffer
TASK 52-22-00-860-003-A
Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder
TASK 52-22-00-860-004-A
Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder
F Door Buffer ** ON A/C NOT FOR ALL
F Door Buffer ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 52-22-12-860-056-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Make sure that the applicable emergency exit door (referred to as door) is opened as required (Ref. AMM TASK 52-22-00-010-001).
   (2) Make sure that the special precaution on the door damper and emergency operation cylinder is completed (Ref. AMM TASK 52-22-00-860-003).
   (3) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the partly opened door.
Subtask 52-22-12-865-057-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
4. Procedure
Subtask 52-22-12-420-052-A ** ON A/C NOT FOR ALL
A. Installation of the Door Buffer
   (1) Put the door buffer (41) into position at the support arm and attach it temporarily with the bolts (42).
   (2) Install the washers (43) and the nuts (44) on the bolts (42).
   (3) Apply a layer of Primer Polyurethane Paint_- Corrosion Inhibiting Structure (Material No.04EAC2) and Top Coat Polyurethane_- Grey Internal Structure (Material No.04JME4) to the bolts (42) and nuts (44).
Subtask 52-22-12-820-050-A ** ON A/C NOT FOR ALL
B. Do the adjustment procedure of the door buffer (Ref. AMM TASK 52-22-00-820-006).
5. Close-up
Subtask 52-22-12-865-058-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
Subtask 52-22-12-410-052-A ** ON A/C NOT FOR ALL
B. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Do the special precaution on the door damper and emergency operation cylinder (Ref. AMM TASK 52-22-00-860-004).
   (3) Close the emergency exit door (Ref. AMM TASK 52-22-00-410-001).
   (4) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.02 06:27:40 UTC