Installation of the Door Buffer
TASK 52-22-12-400-003-A
Installation of the Door Buffer
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 52-22-12-860-056-A ** ON A/C NOT FOR ALL
Subtask 52-22-12-420-052-A ** ON A/C NOT FOR ALL
Subtask 52-22-12-865-058-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:27:40 UTC
Installation of the Door Buffer
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.04EAC2) | Primer Polyurethane Paint_- Corrosion Inhibiting Structure |
| (Material No.04JME4) | Top Coat Polyurethane_- Grey Internal Structure |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-22-00-010-001-A | Opening of the Emergency Exit Doors from the Passenger Compartment |
| TASK 52-22-00-410-001-A | Closing of the Emergency Exit Doors from the Passenger Compartment |
| TASK 52-22-00-820-006-A | Adjustment of the Door Buffer |
| TASK 52-22-00-860-003-A | Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder |
| TASK 52-22-00-860-004-A | Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder |
Subtask 52-22-12-860-056-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the applicable emergency exit door (referred to as door) is opened as required (Ref. AMM TASK 52-22-00-010-001).
(2) Make sure that the special precaution on the door damper and emergency operation cylinder is completed (Ref. AMM TASK 52-22-00-860-003).
(3) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the partly opened door.
Subtask 52-22-12-865-057-A ** ON A/C NOT FOR ALL (1) Make sure that the applicable emergency exit door (referred to as door) is opened as required (Ref. AMM TASK 52-22-00-010-001).
(2) Make sure that the special precaution on the door damper and emergency operation cylinder is completed (Ref. AMM TASK 52-22-00-860-003).
(3) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the partly opened door.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SLIDES/ARM AND WARN/FLT | 15WN | P11 |
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/PAX | 48WV | P05 |
Subtask 52-22-12-420-052-A ** ON A/C NOT FOR ALL
A. Installation of the Door Buffer
(1) Put the door buffer (41) into position at the support arm and attach it temporarily with the bolts (42).
(2) Install the washers (43) and the nuts (44) on the bolts (42).
(3) Apply a layer of Primer Polyurethane Paint_- Corrosion Inhibiting Structure (Material No.04EAC2) and Top Coat Polyurethane_- Grey Internal Structure (Material No.04JME4) to the bolts (42) and nuts (44).
Subtask 52-22-12-820-050-A ** ON A/C NOT FOR ALL 5. Close-up(1) Put the door buffer (41) into position at the support arm and attach it temporarily with the bolts (42).
(2) Install the washers (43) and the nuts (44) on the bolts (42).
(3) Apply a layer of Primer Polyurethane Paint_- Corrosion Inhibiting Structure (Material No.04EAC2) and Top Coat Polyurethane_- Grey Internal Structure (Material No.04JME4) to the bolts (42) and nuts (44).
Subtask 52-22-12-865-058-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 52-22-12-410-052-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SLIDES/ARM AND WARN/FLT | 15WN | P11 |
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/PAX | 48WV | P05 |
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Do the special precaution on the door damper and emergency operation cylinder (Ref. AMM TASK 52-22-00-860-004).
(3) Close the emergency exit door (Ref. AMM TASK 52-22-00-410-001).
(4) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Do the special precaution on the door damper and emergency operation cylinder (Ref. AMM TASK 52-22-00-860-004).
(3) Close the emergency exit door (Ref. AMM TASK 52-22-00-410-001).
(4) Remove the access platform(s).
Door Buffer