Installation of the Door Stay Mechanism
TASK 52-22-12-400-002-A
Installation of the Door Stay Mechanism
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Referenced Information
3. Job Set-up
Subtask 52-22-12-860-055-A ** ON A/C NOT FOR ALL
Subtask 52-22-12-420-051-A ** ON A/C NOT FOR ALL
Subtask 52-22-12-865-055-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:27:40 UTC
Installation of the Door Stay Mechanism
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.04EAC2) | Primer Polyurethane Paint_- Corrosion Inhibiting Structure |
| (Material No.04JME4) | Top Coat Polyurethane_- Grey Internal Structure |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 52-22-00-010-001-A | Opening of the Emergency Exit Doors from the Passenger Compartment |
| TASK 52-22-00-410-001-A | Closing of the Emergency Exit Doors from the Passenger Compartment |
| TASK 52-22-00-860-003-A | Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder |
| TASK 52-22-00-860-004-A | Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder |
Subtask 52-22-12-860-055-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Make sure that the applicable emergency exit door (referred to as door) is opened as required (Ref. AMM TASK 52-22-00-010-001).
(2) Make sure that the special precaution on the door damper and emergency operation cylinder is completed (Ref. AMM TASK 52-22-00-860-003).
(3) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the partly opened door.
Subtask 52-22-12-865-054-A ** ON A/C NOT FOR ALL (1) Make sure that the applicable emergency exit door (referred to as door) is opened as required (Ref. AMM TASK 52-22-00-010-001).
(2) Make sure that the special precaution on the door damper and emergency operation cylinder is completed (Ref. AMM TASK 52-22-00-860-003).
(3) Make sure that the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE is in position below the partly opened door.
B. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SLIDES/ARM AND WARN/FLT | 15WN | P11 |
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/PAX | 48WV | P05 |
Subtask 52-22-12-420-051-A ** ON A/C NOT FOR ALL
A. Installation of the Door Stay Mechanism
(1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Install the release rod (21) on the support arm as follows:
(a) Put the release rod (21) into the related bore of the support arm.
(b) Put the handle (24) over the top-end of the release rod (21).
(c) Put the washers (25) in position between the handle (24) and the support arm.
(d) Install the screws (22) and the washers (23) at the handle (24).
(e) Apply a layer of Primer Polyurethane Paint_- Corrosion Inhibiting Structure (Material No.04EAC2) and Top Coat Polyurethane_- Grey Internal Structure (Material No.04JME4) to the screws (22).
(4) Install the release assy (28) on the support arm as follows:
(a) Put the release assy (28) in its installation position and attach it temporarily with the bolts (29).
(b) Install the washers (27) and the nuts (26) on the bolts (29).
(c) Apply a layer of Primer Polyurethane Paint_- Corrosion Inhibiting Structure (Material No.04EAC2) and Top Coat Polyurethane_- Grey Internal Structure (Material No.04JME4) to the screws (29) and the nuts (26).
(5) Install the lock assy (31) on the support arm as follows:
(a) Put the lock assy (31) together with the washers (32) into their installation position and attach them temporarily with the bolts (30).
(b) Install the washers (33) and the nuts (34) on the bolts (30).
(c) Apply a layer of Primer Polyurethane Paint_- Corrosion Inhibiting Structure (Material No.04EAC2) and Top Coat Polyurethane_- Grey Internal Structure (Material No.04JME4) to the screws (30) and nuts (34).
5. Close-up(1) Make sure that the parts retained from the removed component are clean and in the correct condition.
(2) Do an inspection of the component interfaces and the adjacent area.
(3) Install the release rod (21) on the support arm as follows:
(a) Put the release rod (21) into the related bore of the support arm.
(b) Put the handle (24) over the top-end of the release rod (21).
(c) Put the washers (25) in position between the handle (24) and the support arm.
(d) Install the screws (22) and the washers (23) at the handle (24).
(e) Apply a layer of Primer Polyurethane Paint_- Corrosion Inhibiting Structure (Material No.04EAC2) and Top Coat Polyurethane_- Grey Internal Structure (Material No.04JME4) to the screws (22).
(4) Install the release assy (28) on the support arm as follows:
(a) Put the release assy (28) in its installation position and attach it temporarily with the bolts (29).
(b) Install the washers (27) and the nuts (26) on the bolts (29).
(c) Apply a layer of Primer Polyurethane Paint_- Corrosion Inhibiting Structure (Material No.04EAC2) and Top Coat Polyurethane_- Grey Internal Structure (Material No.04JME4) to the screws (29) and the nuts (26).
(5) Install the lock assy (31) on the support arm as follows:
(a) Put the lock assy (31) together with the washers (32) into their installation position and attach them temporarily with the bolts (30).
(b) Install the washers (33) and the nuts (34) on the bolts (30).
(c) Apply a layer of Primer Polyurethane Paint_- Corrosion Inhibiting Structure (Material No.04EAC2) and Top Coat Polyurethane_- Grey Internal Structure (Material No.04JME4) to the screws (30) and nuts (34).
Subtask 52-22-12-865-055-A ** ON A/C NOT FOR ALL
A. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
Subtask 52-22-12-410-051-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 121VU | EIS/SLIDES/ARM AND WARN/FLT | 15WN | P11 |
| 121VU | EIS/SLIDES/ARM AND WARN/GND | 13WN | P10 |
| 121VU | EIS/SDAC1 AND 2/DOOR/DET/PAX | 48WV | P05 |
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Do the special precaution on the door damper and emergency operation cylinder (Ref. AMM TASK 52-22-00-860-004).
(3) Close the emergency exit door (Ref. AMM TASK 52-22-00-410-001).
(4) Remove the access platform(s).
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Do the special precaution on the door damper and emergency operation cylinder (Ref. AMM TASK 52-22-00-860-004).
(3) Close the emergency exit door (Ref. AMM TASK 52-22-00-410-001).
(4) Remove the access platform(s).
Door Stay Mechanism