W DOC AIRBUS | AMM A320F

General Visual Inspection of Door Stop Assemblies and Locking Hook on Aft Emergency Exit Doors, LH/RH


TASK 52-22-11-200-008-A
General Visual Inspection of Door Stop Assemblies and Locking Hook on Aft Emergency Exit Doors, LH/RH


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 835
ZONE: 845
1. Reason for the Job
Refer to the MPD TASK: 522206-01
GENERAL VISUAL INSPECTION OF DOOR STOP ASSEMBLIES AND LOCKING HOOK ON AFT EMERGENCY EXIT DOORS, LH/RH
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
835
MID PASSENGER/CREW DOOR
845
MID PASSENGER/CREW DOOR
835, 845
834, 844
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 52-22-00-010-001-A
Opening of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-410-001-A
Closing of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-21-000-003-A
Removal of the Locking Shaft Mechanism (60" Door)
TASK 52-22-21-400-003-A
Installation of the Locking Shaft Mechanism (60" Door)
TASK 52-22-31-000-002-A
Removal of the Stop and Guide Fittings from the Door Frame
TASK 52-22-31-400-002-A
Installation of the Stop and Guide Fittings at the Door Frame
3. Job Set-up
Subtask 52-22-11-010-058-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at aft emergency-exit door 834( 844).
   (2) Open aft emergency-exit door 834( 844) (Ref. AMM TASK 52-22-00-010-001).
Subtask 52-22-11-010-058-B ** ON A/C NOT FOR ALL
A. Get Access
   (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at aft emergency-exit door 835( 845).
   (2) Open aft emergency-exit door 835( 845) (Ref. AMM TASK 52-22-00-010-001).
Subtask 52-22-11-110-052-A ** ON A/C NOT FOR ALL
B. Preparation of the Inspection Area
   (1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
   (2) If not, clean the inspection area with Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) .
4. Procedure
Subtask 52-22-11-210-056-A ** ON A/C NOT FOR ALL
A. Inspection
   (1) Do a general visual inspection of the door stop assemblies and the locking hook on the aft emergency-exit doors, on the right and left sides, for damage or discontinuities.
   (2) Make sure that there is no damage.
   (3) If you find damage, replace the locking hook and/or the adjustable stop fitting (Ref. AMM TASK 52-22-21-000-003) and (Ref. AMM TASK 52-22-21-400-003) and/or (Ref. AMM TASK 52-22-31-000-002) and (Ref. AMM TASK 52-22-31-400-002).
5. Close-up
Subtask 52-22-11-410-058-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close aft emergency-exit door 834( 844) (Ref. AMM TASK 52-22-00-410-001).
   (3) Remove the access platform(s).
Subtask 52-22-11-410-058-B ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close aft emergency-exit door 835( 845) (Ref. AMM TASK 52-22-00-410-001).
   (3) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.02 06:27:40 UTC