W DOC AIRBUS | AMM A320F

Detailed Inspection of Cylinder Assembly


TASK 52-22-11-200-004-A
Detailed Inspection of Cylinder Assembly


ZONE: 833
ZONE: 834
ZONE: 835
ZONE: 843
ZONE: 844
ZONE: 845
FIN: 1600WM ** ON A/C NOT FOR ALL
FIN: 1601WM ** ON A/C NOT FOR ALL
FIN: 1602WM ** ON A/C NOT FOR ALL
FIN: 1603WM ** ON A/C NOT FOR ALL
1. Reason for the Job
Refer to the MPD TASK: 522200-04
DETAILED INSPECTION OF CYLINDER ASSEMBLY
NOTE: This task is not applicable to the deactivated emergency doors.
2. Job Set-up Information
 A. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
833
EMERGENCY EXITS
834
EMERGENCY EXITS
835
MID PASSENGER/CREW DOOR
843
EMERGENCY EXITS
844
EMERGENCY EXITS
845
MID PASSENGER/CREW DOOR
835, 845
833, 834, 843, 844
 B. Referenced Information
REFERENCE
DESIGNATION
TASK 20-28-00-200-001-A
Detailed Inspection of Bonding Leads on Access Panels, Doors and Movable Surfaces
TASK 52-22-00-010-001-A
Opening of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-410-001-A
Closing of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-614-002-A
Charging of the Door Damper and Emergency Operation Cylinders at the Emergency Exit Doors
TASK 52-22-00-860-003-A
Special Precaution before Maintenance on the Door Damper and Emergency Operation Cylinder
TASK 52-22-00-860-004-A
Special Precaution after Maintenance on the Door Damper and Emergency Operation Cylinder
TASK 52-22-14-000-001-A
Removal of the Door Damper and Emergency Operation Cylinder
TASK 52-22-14-400-001-A
Installation of the Door Damper and Emergency Operation Cylinder
F Cylinder Assembly ** ON A/C NOT FOR ALL
F Cylinder Assembly ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 52-22-11-010-056-A ** ON A/C NOT FOR ALL
A. Get Access
   (1) Open emergency exit door 833, 834, 843 or 844 (Ref. AMM TASK 52-22-00-010-001).
   (2) Do the special precaution on the door damper and emergency operation cylinder (Ref. AMM TASK 52-22-00-860-003).
Subtask 52-22-11-010-056-B ** ON A/C NOT FOR ALL
A. Get Access
   (1) Open emergency exit door 835 or 845 (Ref. AMM TASK 52-22-00-010-001).
   (2) Do the special precaution on the door damper and emergency operation cylinder (Ref. AMM TASK 52-22-00-860-003).
4. Procedure
Subtask 52-22-11-210-052-A ** ON A/C NOT FOR ALL
A. Inspection
F Cylinder Assembly ** ON A/C NOT FOR ALL
F Cylinder Assembly ** ON A/C NOT FOR ALL
   (1) Do a detailed inspection of the door damper and emergency operation cylinder (referred to as "door damper") as follows:
     (a) Make sure that there is no fluid leakage around the door damper.
     (b) Make sure that there are no corrosion, cracks, marks or dents on the door damper.
     (c) Make sure that the door damper is correctly attached.
     (d) Make sure that the paint is in the correct condition.
     (e) If you find any type of damage, replace the door damper (Ref. AMM TASK 52-22-14-000-001) and (Ref. AMM TASK 52-22-14-400-001).
   (2) Examine the bonding straps of the door damper and their attachments for correct condition (Ref. AMM TASK 20-28-00-200-001).
   (3) Make sure that the pressure of the door damper shown on the pressure gage is correct.
   (4) If the pressure is not correct, fill the door damper (Ref. AMM TASK 52-22-00-614-002).
5. Close-up
Subtask 52-22-11-410-056-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Do the special precaution on the door damper and emergency operation cylinder (Ref. AMM TASK 52-22-00-860-004).
   (3) Close emergency exit door 833, 834, 843 or 844 (Ref. AMM TASK 52-22-00-410-001).
Subtask 52-22-11-410-056-B ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Do the special precaution on the door damper and emergency operation cylinder (Ref. AMM TASK 52-22-00-860-004).
   (3) Close emergency exit door 835 or 845 (Ref. AMM TASK 52-22-00-410-001).
[Rev.10 from 2021] 2026.04.02 06:27:40 UTC