W DOC AIRBUS | AMM A320F

Replacement of the Charging Valve and Percussion Mechanism Seals


TASK 52-22-00-860-005-A
Replacement of the Charging Valve and Percussion Mechanism Seals


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 833
ZONE: 834
ZONE: 835
ZONE: 843
ZONE: 844
ZONE: 845
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
Torque wrench: range to between 3.15 and 2.85 m.daN (23.23 and 21.02 lbf.ft ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.02BBB9)
Mineral Hydraulic Fluid-Damper - -
(Material No.14QFB1)
Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
833
EMERGENCY EXITS
834
EMERGENCY EXITS
835
MID PASSENGER/CREW DOOR
843
EMERGENCY EXITS
844
EMERGENCY EXITS
845
MID PASSENGER/CREW DOOR
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
5
SHEAR PIN
AIPC 52-22-14-01-030
16
PACKINGS
AIPC 52-22-14-01-070
15
SEAL
AIPC 52-22-14-01-080
9
PACKING
AIPC 52-22-14-01-110
9
PACKING
AIPC 52-22-14-01-140
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 24-42-00-862-001-A
De-energize the Ground Service Network Supplied from the External Power
TASK 52-22-00-010-001-A
Opening of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-410-001-A
Closing of the Emergency Exit Doors from the Passenger Compartment
TASK 52-22-00-614-002-A
Charging of the Door Damper and Emergency Operation Cylinders at the Emergency Exit Doors
F Charging Valve Seal ** ON A/C NOT FOR ALL
F Charging Valve Seal ** ON A/C NOT FOR ALL
3. Job Set-up
Subtask 52-22-00-861-054-A ** ON A/C NOT FOR ALL
A. Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 52-22-00-865-066-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
Subtask 52-22-00-010-076-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Open the applicable emergency exit door (referred to as the door) (Ref. AMM TASK 52-22-00-010-001).
   (2) Make sure that the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE is in position below the applicable door.
Subtask 52-22-00-860-087-A ** ON A/C NOT FOR ALL
D. Aircraft Maintenance Configuration
F Charging Valve Seal ** ON A/C NOT FOR ALL
F Charging Valve Seal ** ON A/C NOT FOR ALL
   (1) Make sure that the rigging pin (4) is correctly installed in the percussion mechanism.
   (2) Remove and discard the shear pin (5).
   (3) Set the release lever (3) as follows:
     (a) Remove and discard the lockwire from the knurled screw (2).
     (b) Loosen the knurled screw (2) sufficiently until you can move the release lever (3).
     (c) Move the release lever (3) rearward until it is free from the guide (6).
     (d) Turn the release lever (3) through 90 degrees clockwise to get access to the striker assembly (17).
     (e) Tighten the knurled screw (2) sufficiently to safety the release lever (3).
   (4) Remove the dust cap (11) from the pressure charging valve (10).
   (5) Operate the pressure charging valve (10) until the door damper and emergency operation cylinder (1) is fully depressurized.
4. Procedure
Subtask 52-22-00-020-052-A ** ON A/C NOT FOR ALL
A. Removal of the Percussion Mechanism Seal (15) and the Packings (16)
WARNING: MAKE SURE THAT THE DOOR-DAMPER AND EMERGENCY OPERATION CYLINDER IS FULLY DEPRESSURIZED BEFORE YOU REMOVE THE STRIKER ASSEMBLY. IF NOT, REMAINING PRESSURE CAN CAUSE INJURY.
   (1) Remove the striker assembly (17) as follows:
     (a) Remove the screws (18) from the striker assembly (17).
     (b) Carefully remove the striker assembly (17) from the housing assembly (8).
     (c) Remove the diaphragm (14), the spacer (12) and the spring (13) from the striker assembly (17).
     (d) Remove and discard the packings (16) from the striker assembly (17).
     (e) Remove and discard the seal (15) from the striker assembly (17).
Subtask 52-22-00-020-053-A ** ON A/C NOT FOR ALL
B. Removal of the Charging Valve Packing (9)
   (1) Remove the charging valve (10) from the housing assembly (8).
   (2) Remove and discard the packing (9) from the charging valve (10).
Subtask 52-22-00-860-088-A ** ON A/C NOT FOR ALL
C. Preparation for Installation
   (1) Make sure that the parts retained from the removed component are clean and in the correct condition.
   (2) Clean the component interfaces and the adjacent area.
   (3) Do an inspection of the component interfaces and the adjacent area.
Subtask 52-22-00-420-052-A ** ON A/C NOT FOR ALL Subtask 52-22-00-420-053-A ** ON A/C NOT FOR ALL 5. Close-up
Subtask 52-22-00-860-089-A ** ON A/C NOT FOR ALL
A. Put the system back to the serviceable condition.
   (1) Charge the pressure accumulator to the correct pressure (
Ref. AMM TASK 52-22-00-614-002).
   (2) Set the release lever (3) to its armed position as follows:
     (a) Loosen the knurled screw (2) and turn the release lever (3) through 90 degrees (in a counterclockwise direction) until it engages with the guide (6).
     (b) Push the release lever (3) forward through the guide (6).
     (c) Make sure that the release lever (3) is fully engaged with the guide (6).
     (d) Move the release lever (3) fully forward and tighten the knurled screw (2) to hold the release lever (3) in the armed position.
     (e) Safety the knurled screw (2) with the lockwire 14QFB1Wire-Locking Dia: 0.8 mm CRES Nickel Alloy -.
   (3) Remove the rigging pin (4) from the housing assembly (8).
Subtask 52-22-00-865-067-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUEIS/SLIDES/ARM AND WARN/FLT15WNP11
121VUEIS/SLIDES/ARM AND WARN/GND13WNP10
121VUEIS/SDAC1 AND 2/DOOR/DET/PAX48WVP05
Subtask 52-22-00-410-066-A ** ON A/C NOT FOR ALL
C. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the applicable emergency exit door (Ref. AMM TASK 52-22-00-410-001).
   (3) De-energize the ground service network (Ref. AMM TASK 24-42-00-862-001).
   (4) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.02 06:27:36 UTC