Set the AFT OWD Handle Back to the Closed Position
TASK 52-22-00-720-805-A
Set the AFT OWD Handle Back to the Closed Position
Refer to the MPD TASK: 522101-06
SET THE AFT OWD HANDLE BACK TO THE CLOSED POSITION.
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 52-22-00-860-110-A ** ON A/C NOT FOR ALL
Subtask 52-22-00-710-061-A ** ON A/C NOT FOR ALL
Subtask 52-22-00-410-077-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:27:38 UTC
Set the AFT OWD Handle Back to the Closed Position
WARNING:
WHEN YOU DO WORK ON THE OVERWING EMERGENCY DOOR, BE CAREFUL NOT TO PULL THE OWD HANDLE. THIS PREVENTS SUDDEN MOVEMENT OF THE DOOR AND ACCIDENTAL DEPLOYMENT OF THE EMERGENCY SLIDE. THIS CAN CAUSE INJURY TO PERSONS AND/OR DAMAGE TO EQUIPMENT.
1. Reason for the JobRefer to the MPD TASK: 522101-06
SET THE AFT OWD HANDLE BACK TO THE CLOSED POSITION.
NOTE: You must do this procedure for the two activated overwing emergency exit-doors during the same maintenance check.
NOTE: This task is not applicable for the deactivated overwing emergency exit-doors.
2. Job Set-up InformationA. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 834 | EMERGENCY EXITS |
| 844 | EMERGENCY EXITS |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-42-00-861-001-A | Energize the Ground Service Network from the External Power |
| TASK 24-42-00-862-001-A | De-energize the Ground Service Network Supplied from the External Power |
Subtask 52-22-00-860-110-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
Subtask 52-22-00-010-090-A ** ON A/C NOT FOR ALL (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
B. Get Access
(1) Remove the handle cover (2) of the overwing emergency exit-door (1).
4. Procedure(1) Remove the handle cover (2) of the overwing emergency exit-door (1).
Subtask 52-22-00-710-061-A ** ON A/C NOT FOR ALL
A. Set the Aft handle back to the closed position
(1) Push the inboard handle assembly (3).
(2) Make sure that the over-centering mechanism (4) touches the mechanical end stop (5).
5. Close-up(1) Push the inboard handle assembly (3).
(2) Make sure that the over-centering mechanism (4) touches the mechanical end stop (5).
Subtask 52-22-00-410-077-A ** ON A/C NOT FOR ALL
A. Close access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the handle cover (2) on the overwing emergency exit-door (1).
Subtask 52-22-00-860-111-A ** ON A/C NOT FOR ALL (1) Make sure that the work area is clean and clear of tools and other items.
(2) Install the handle cover (2) on the overwing emergency exit-door (1).
B. Aircraft Maintenance Configuration
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
(1) De-energize the ground service network
(Ref. AMM TASK 24-42-00-862-001).
Set the Aft OWD Handle Back to the Closed Position