Functional Check of Manual and Automatic Slide Release Signal
TASK 52-22-00-720-803-A
Functional Check of Manual and Automatic Slide Release Signal
Refer to the MPD TASK: 522101-04
FUNCTIONAL CHECK OF MANUAL AND AUTOMATIC SLIDE RELEASE SIGNAL
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Consumable Materials
C. Work Zones and Access Panels
D. Referenced Information
3. Job Set-up
Subtask 52-22-00-010-083-A ** ON A/C NOT FOR ALL
Subtask 52-22-00-720-053-A ** ON A/C NOT FOR ALL
Subtask 52-22-00-860-102-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:27:38 UTC
Functional Check of Manual and Automatic Slide Release Signal
WARNING:
MAKE SURE THAT THE LOCK PIN IS CORRECTLY INSTALLED IN THE REGULATOR VALVE ASSEMBLY OF THE INFLATION RESERVOIR. THIS SAFETIES ALL COMPONENTS OF THE INFLATION SYSTEM IN OPERATION AND PREVENTS ACCIDENTAL:
- DISCHARGE OF THE INFLATION RESERVOIR
- DEPLOYMENT OF THE ESCAPE SLIDE
WARNING:
BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the JobRefer to the MPD TASK: 522101-04
FUNCTIONAL CHECK OF MANUAL AND AUTOMATIC SLIDE RELEASE SIGNAL
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| TLW101 | 1 | TEST TOOL-RELEASE CABLE,ESCAPE SLIDE |
| REFERENCE | DESIGNATION |
|---|---|
| (Material No.14QFB1) | Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 151 | AFT CARGO COMPARTMENT |
| 152 | AFT CARGO COMPARTMENT |
| 833, 834, 843, 844 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 25-62-00-081-001-A | Special Precautions after Work on the Offwing Escape-Slide Systems |
| TASK 25-62-00-481-001-A | Special Precautions before Work on the Offwing Escape-Slide Systems |
| TASK 25-62-00-640-001-A | Lubrication of the Flexible Control Assembly |
| TASK 52-22-00-410-802-A | Closing of the Overwing Emergency-Exit Door from the Passenger Compartment |
Subtask 52-22-00-010-083-A ** ON A/C NOT FOR ALL
A. Get Access
(1) Open the door (5) of the overhead stowage compartment (4).
(2) Push the quick-release fasteners (19) to release the cover (6).
(3) Carefully remove the cover (6).
Subtask 52-22-00-860-101-A ** ON A/C NOT FOR ALL (1) Open the door (5) of the overhead stowage compartment (4).
(2) Push the quick-release fasteners (19) to release the cover (6).
(3) Carefully remove the cover (6).
B. Preparation for the Test
(1) Make sure that the overwing emergency door (1) is correctly closed and the release lever (21) is in front of the lever (20) (Ref. AMM TASK 52-22-00-410-802).
(2) Install the lock-pin assembly in the operating head of the inflation reservoir (7) to prevent accidental operation of the inflation reservoir (7) (Ref. AMM TASK 25-62-00-481-001).
(3) Remove the inflation reservoir assembly from the flexible control assembly as follows:
(b) Loosen the knurled sleeve nut (18).
(c) Remove the two collets (10) from the flexible control assembly.
(d) Disconnect the inflation cable (13) from the release cable (11).
(4) Install the TLW101 TEST TOOL-RELEASE CABLE,ESCAPE SLIDE on the flexible control assembly as follows:
(b) Engage the adapter (12) with the release cable (11).
(c) Put the collets (10) in position around the joint.
(d) Turn the knurled sleeve nut (14) to safety the connection between the TLW101 TEST TOOL-RELEASE CABLE,ESCAPE SLIDE and the flexible control assembly.
(e) Make sure that the pointer of the TLW101 TEST TOOL-RELEASE CABLE,ESCAPE SLIDE touches the stop (17) of the housing (15).
(f) Measure the initial position of the pointer at the housing scale (16).
4. Procedure(1) Make sure that the overwing emergency door (1) is correctly closed and the release lever (21) is in front of the lever (20) (Ref. AMM TASK 52-22-00-410-802).
(2) Install the lock-pin assembly in the operating head of the inflation reservoir (7) to prevent accidental operation of the inflation reservoir (7) (Ref. AMM TASK 25-62-00-481-001).
(3) Remove the inflation reservoir assembly from the flexible control assembly as follows:
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
CAUTION:
DO NOT PUSH THE END OF THE WIRE INTO THE WIRE-CONTROL ASSEMBLY. THIS CAN CAUSE A KINK IN THE WIRE.
(a) Remove and discard the lockwire from the knurled sleeve nut (18). (b) Loosen the knurled sleeve nut (18).
(c) Remove the two collets (10) from the flexible control assembly.
(d) Disconnect the inflation cable (13) from the release cable (11).
(4) Install the TLW101 TEST TOOL-RELEASE CABLE,ESCAPE SLIDE on the flexible control assembly as follows:
CAUTION:
DO NOT PUT WEIGHT ON THE FWD PULLEY WHEN YOU CONNECT THE WIRE- CONTROL ASSEMBLY TO THE FLEXIBLE CONTROL-ASSEMBLY. WEIGHT ON THE PULLEY CAUSES TENSION IN THE WIRE, WHICH CAN CAUSE THE END OF THE WIRE TO BREAK.
(a) Remove the cover cap (9) from the TLW101 TEST TOOL-RELEASE CABLE,ESCAPE SLIDE. (b) Engage the adapter (12) with the release cable (11).
(c) Put the collets (10) in position around the joint.
(d) Turn the knurled sleeve nut (14) to safety the connection between the TLW101 TEST TOOL-RELEASE CABLE,ESCAPE SLIDE and the flexible control assembly.
(e) Make sure that the pointer of the TLW101 TEST TOOL-RELEASE CABLE,ESCAPE SLIDE touches the stop (17) of the housing (15).
(f) Measure the initial position of the pointer at the housing scale (16).
NOTE: The pointer does not accurately stay at zero because of the weight of the TLW101 TEST TOOL-RELEASE CABLE,ESCAPE SLIDE.
Subtask 52-22-00-720-053-A ** ON A/C NOT FOR ALL
A. Functional Check of the Manual and Automatic Slide Release Signal
(1) Do this test to examine:
(2) Do the lubrication procedure of the flexible control assembly (Ref. AMM TASK 25-62-00-640-001) if:
5. Close-up(1) Do this test to examine:
- The automatic operation of the slide release mechanism when you open and close the overwing emergency-exit door (1)
- The manual operation of the slide release mechanism
- The operation of the overwing emergency-exit-door locking-mechanism from the inner and the outer side.
| ACTION | RESULT |
|---|---|
| 1.In the center of the cabin: | In the center of the cabin: |
|
|
|
|
|
|
|
|
|
|
|
|
| 2.On the overwing emergency-exit-door structure: | On the overwing emergency-exit-door structure: |
| |
|
|
| 3.In the center of the cabin: | In the center of the cabin: |
| |
| |
|
|
| |
|
|
- The pointer of the TLW101 TEST TOOL-RELEASE CABLE,ESCAPE SLIDE does not stay in the green area of the scale (16)
or - The travel value is not a minimum of 50.0 mm (1.97 in.).
Subtask 52-22-00-860-102-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to the serviceable condition.
(1) Remove the TLW101 TEST TOOL-RELEASE CABLE,ESCAPE SLIDE from the flexible control assembly as follows:
(b) Disengage the adapter (12) from the release cable (11).
(2) Connect the flexible control assembly to the inflation reservoir assembly as follows:
(b) Put the collets (10) in position and tighten the knurled sleeve nut (18).
(3) Safety the knurled sleeve nut (18):
14QFB1 Wire-Locking Dia: 0.8 mm CRES Nickel Alloy - .
(4) Remove the lock-pin assembly from the operating head of the inflation reservoir (7) and put it into its bag (8) (Ref. AMM TASK 25-62-00-081-001).
Subtask 52-22-00-410-071-A ** ON A/C NOT FOR ALL (1) Remove the TLW101 TEST TOOL-RELEASE CABLE,ESCAPE SLIDE from the flexible control assembly as follows:
CAUTION:
DO NOT PUSH THE END OF THE WIRE INTO THE WIRE-CONTROL ASSEMBLY. THIS CAN CAUSE A KINK IN THE WIRE.
(a) Loosen the knurled sleeve nut (14) and disassemble the two collets (10) from the flexible control assembly. (b) Disengage the adapter (12) from the release cable (11).
(2) Connect the flexible control assembly to the inflation reservoir assembly as follows:
CAUTION:
DO NOT PUT WEIGHT ON THE FWD PULLEY WHEN YOU CONNECT THE WIRE- CONTROL ASSEMBLY TO THE FLEXIBLE CONTROL-ASSEMBLY. WEIGHT ON THE PULLEY CAUSES TENSION IN THE WIRE, WHICH CAN CAUSE THE END OF THE WIRE TO BREAK.
(a) Engage the inflation cable (13) to the release cable (11). (b) Put the collets (10) in position and tighten the knurled sleeve nut (18).
NOTE: When you install the collets (10), one of the slots must point to you.
(c) While you tighten the knurled sleeve nut (18), do a visual check to make sure that the wire stays connected. (3) Safety the knurled sleeve nut (18):
WARNING:
USE PROTECTIVE GOGGLES AND GLOVES WHEN YOU REMOVE OR INSTALL LOCKWIRE. EACH TIME YOU CUT LOCKWIRE, REMOVE AND DISCARD IT IMMEDIATELY. LOOSE LOCKWIRE CAN CUT YOU OR MAKE YOU BLIND, AND/OR CAN CAUSE DAMAGE.
(a) Safety the knurled sleeve nut (18) with the (4) Remove the lock-pin assembly from the operating head of the inflation reservoir (7) and put it into its bag (8) (Ref. AMM TASK 25-62-00-081-001).
B. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Put the cover (6) in position on the overhead stowage compartment (4).
(3) Make sure that you can see the pressure gage of the inflation reservoir (7) through the inspection window.
(4) Push the quick-release fastener (19) to install the cover (6).
(5) Close the door (5) of the overhead stowage compartment (4).
(6) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Put the cover (6) in position on the overhead stowage compartment (4).
(3) Make sure that you can see the pressure gage of the inflation reservoir (7) through the inspection window.
(4) Push the quick-release fastener (19) to install the cover (6).
(5) Close the door (5) of the overhead stowage compartment (4).
(6) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
Slide Release Signal