Detailed Inspection of Emergency Overwing Door Seals


TASK 52-22-00-220-002-A
Detailed Inspection of Emergency Overwing Door Seals


WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
ZONE: 833
ZONE: 834
ZONE: 843
ZONE: 844
1. Reason for the Job
Refer to the MPD TASK: 522101-07
DETAILED INSPECTION OF EMERGENCY OVERWING DOOR SEALS.
NOTE: This task is not applicable to the deactivated overwing emergency-exit door.
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
1
WARNING NOTICE(S)
98D27803000000
2
LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
(Material No.14SBA1)
Textile-Lint free Cotton -
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
833
EMERGENCY EXITS
834
EMERGENCY EXITS
843
EMERGENCY EXITS
844
EMERGENCY EXITS
833, 834, 843, 844
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 12-00-00-481-002-A
Installation of the Wingrip
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 27-00-00-080-002-A
Removal of the Flap/Slat Control-Lever Locking Tool (98D27803000000)
TASK 27-00-00-480-002-A
Installation of the Flap/Slat Control-Lever Locking Tool (98D27803000000)
TASK 52-22-00-010-802-A
Opening of the Overwing Emergency-Exit Door from the Passenger Compartment
TASK 52-22-00-010-803-A
Opening of the Overwing Emergency-Exit Door from the Outside
TASK 52-22-00-410-802-A
Closing of the Overwing Emergency-Exit Door from the Passenger Compartment
3. Job Set-up
Subtask 52-22-00-860-137-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Install the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION on the slats and flaps control lever (Ref. AMM TASK 27-00-00-480-002).
   (3) Put the WARNING NOTICE(S) in position in the cockpit to tell persons not to operate the slats and flaps control lever.
Subtask 52-22-00-865-083-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SEC1/NORM/SPLY21CE1B03
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB02
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB01
105VUFLT CTL/SEC1/STBY SPLY22CEB01
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
121VUFLIGHT CONTROLS/SEC3/SPLY21CE3Q19
121VUFLIGHT CONTROLS/SEC2/SPLY21CE2Q18
121VUFLIGHT CONTROLS/SLT/CTL/SYS27CVR21
122VUFLIGHT LOCK OWD40WNU16
Subtask 52-22-00-010-111-A ** ON A/C NOT FOR ALL
C. Get Access
   (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at overwing emergency-exit door 833, 843, 834 or 844.
   (2) Put on a safety harness:
WARNING: YOU MUST PUT ON AND ATTACH A SAFETY HARNESS BEFORE YOU START WORK:
  • ON THE THS OR IN THE REAR FUSELAGE
  • ON TOP OF THE WINGS OR PYLONS.
WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
     (a) Install the individual pad system (Ref. AMM TASK 12-00-00-481-002).
     (b) Put on and attach a safety harness before you start work in the work area.
   (3) Open overwing emergency-exit door 833, 843, 834 or 844 (Ref. AMM TASK 52-22-00-010-803) or (Ref. AMM TASK 52-22-00-010-802).
   (4) Make sure that the applicable overwing emergency-exit door stays in the fully open position for a minimum of one hour. This is to make sure that the ice melts and the water drains correctly.
Subtask 52-22-00-110-051-A ** ON A/C NOT FOR ALL
D. Preparation of the Inspection Area
   (1) Make sure that the inspection area is sufficiently clean to do a satisfactory inspection of the area.
   (2) If the inspection area is not sufficiently clean, clean it with the Non Aqueous Cleaner-General - - (Material No.08BAA9) and the Textile-Lint free Cotton - (Material No.14SBA1) .
4. Procedure
Subtask 52-22-00-220-052-A ** ON A/C NOT FOR ALL
A. Inspection
   (1) Do a detailed inspection of the overwing emergency-exit-door seals.
   (2) Make sure that the overwing emergency-exit-door seals have no damage.
   (3) Make sure that the overwing emergency-exit-door seals are attached correctly.
   (4) Make sure that the drain and the vent holes have no blockage or contamination.
   (5) If necessary, clean the drain and the vent holes with the Textile-Lint free Cotton - (Material No.14SBA1) .
5. Close-up
Subtask 52-22-00-410-093-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close overwing emergency-exit door 833, 843, 834 or 844 (Ref. AMM TASK 52-22-00-410-802).
   (3) Remove the access platform(s).
Subtask 52-22-00-865-084-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUFLIGHT CONTROLS/SEC1/NORM/SPLY21CE1B03
49VUFLIGHT CONTROLS/FLP/CTL AND MONG/SYS16CVB02
49VUFLIGHT CONTROLS/SLT/CTL AND MONG/SYS15CVB01
105VUFLT CTL/SEC1/STBY SPLY22CEB01
121VUFLIGHT CONTROLS/FLP/CTL AND/MONG/SYS28CVQ21
121VUFLIGHT CONTROLS/SEC3/SPLY21CE3Q19
121VUFLIGHT CONTROLS/SEC2/SPLY21CE2Q18
121VUFLIGHT CONTROLS/SLT/CTL/SYS27CVR21
122VUFLIGHT LOCK OWD40WNU16
Subtask 52-22-00-860-138-A ** ON A/C NOT FOR ALL
C. Put the aircraft back to its initial configuration.
   (1) Remove the WARNING NOTICE(S).
   (2) Remove the 98D27803000000 LOCKING TOOL-FLAP SLAT LEVER,INT. POSITION from the slats and flaps control lever (Ref. AMM TASK 27-00-00-080-002).
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).