Deactivation of the Family Aircraft with One Pair of Cabin Overwing Exits and Aft Cabin Doors not Deactivated
TASK 52-21-00-040-802-A
Deactivation of the Family Aircraft with One Pair of Cabin Overwing Exits and Aft Cabin Doors not Deactivated
MMEL 52-10-02A
CABIN OVERWING EXIT
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
3. Procedure
Subtask 52-21-00-040-050-B ** ON A/C NOT FOR ALL
Subtask 52-21-00-410-065-B ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:27:33 UTC
Deactivation of the Family Aircraft with One Pair of Cabin Overwing Exits and Aft Cabin Doors not Deactivated
ZONE: 833
ZONE: 834
ZONE: 843
ZONE: 844
Task Summary
1. Reason for the JobZONE: 834
ZONE: 843
ZONE: 844
Task Summary
| Access | Test | Specific Tools | Mhr | E/T | Nb Men |
|---|---|---|---|---|---|
| NO | YES | NO | 0.1 | 0.1 | 1 |
MMEL 52-10-02A
CABIN OVERWING EXIT
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | COVER - BLANKING |
| No specific | AR | PLACARD |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 833 | EMERGENCY EXITS |
| 834 | EMERGENCY EXITS |
| 843 | EMERGENCY EXITS |
| 844 | EMERGENCY EXITS |
Subtask 52-21-00-040-050-B ** ON A/C NOT FOR ALL
A. Deactivation of the Cabin Overwing Exit
(1) Put a temporary "DO NOT USE" PLACARD at each deactivated door to tell persons not to use them.
(2) Put a temporary "DO NOT USE" PLACARD on each of the remaining seats to tell persons not to use them.
(3) For the deactivated exit, put a COVER - BLANKING on the applicable arrow of the related EXIT marking sign and on the related wall-mounted EXIT marking sign.
(a) Put a COVER - BLANKING on the applicable arrow of the EXIT location sign in the ceiling.
4. Close-up(1) Put a temporary "DO NOT USE" PLACARD at each deactivated door to tell persons not to use them.
(2) Put a temporary "DO NOT USE" PLACARD on each of the remaining seats to tell persons not to use them.
(3) For the deactivated exit, put a COVER - BLANKING on the applicable arrow of the related EXIT marking sign and on the related wall-mounted EXIT marking sign.
(a) Put a COVER - BLANKING on the applicable arrow of the EXIT location sign in the ceiling.
Subtask 52-21-00-410-065-B ** ON A/C NOT FOR ALL
A. Close Access
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Make an entry in the logbook.
(1) Make sure that the work area is clean and clear of tools and other items.
(2) Make an entry in the logbook.