W DOC AIRBUS | AMM A320F

Replacement of the Extruded Rubber Seal


TASK 52-11-18-960-801-A
Replacement of the Extruded Rubber Seal


WARNING: DO NOT OPEN THE PASSENGER/CREW DOOR IF THE WIND SPEED IS MORE THAN 65 KNOTS.
WARNING: STOP THE OPENING PROCEDURE IF THE RED WARNING LIGHT FLASHES. IF THE RED WARNING LIGHT FLASHES, REMAINING PRESSURE CAN CAUSE THE DOOR TO OPEN SUDDENLY AND CAN:
  • KILL OR CAUSE SERIOUS INJURY TO PERSONS
  • CAUSE DAMAGE TO THE AIRCRAFT.
WARNING: BE CAREFUL WHEN YOU USE CONSUMABLE MATERIALS. OBEY THE MATERIAL MANUFACTURER'S INSTRUCTIONS AND YOUR LOCAL REGULATIONS.
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
AR
ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE
No specific
1
BRUSH - BRISTLED, STIFF
No specific
1
SCRAPER - NON METALLIC
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.05RAB9)
Adhesive Film Tape-- Aluminium Foil -
(Material No.06CMD9)
Silicone Adhesive Sealant-General Purpose One part legacy
(Material No.08BAA9)
Non Aqueous Cleaner-General - -
 C. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
1
EXTRUDED RUBBER SEAL
AIPC 52-11-18-01-460
 D. Referenced Information
REFERENCE
DESIGNATION
TASK 52-10-00-010-001-A
Opening of the Passenger/Crew Door
TASK 52-10-00-410-001-A
Closing of the Passenger/Crew Door
TASK 52-10-00-860-001-A
Special Precautions before Work on the Passenger/Crew Door
TASK 52-10-00-860-002-A
Special Precautions after Work on the Passenger/Crew Door
3. Job Set-up
Subtask 52-11-18-941-055-A
A. Get Access
   (1) Put the ACCESS PLATFORM 5M (16 FT)- ADJUSTABLE in position at zone 831 or 841.
   (2) Open the door 831 or 841 (Ref. AMM TASK 52-10-00-010-001).
   (3) Obey the special precautions before you start work on the door (Ref. AMM TASK 52-10-00-860-001).
4. Procedure
Subtask 52-11-18-960-050-A
A. Replacement of the Extruded Rubber Seal
   (1) Remove the Adhesive Film Tape-- Aluminium Foil - (Material No.05RAB9) .
   (2) Remove the defective extruded rubber seal (1).
   (3) Remove the remaining adhesive with the SCRAPER - NON METALLIC and the BRUSH - BRISTLED, STIFF.
   (4) Clean the surfaces with Non Aqueous Cleaner-General - - (Material No.08BAA9) .
   (5) Install the new AIPC 52-11-18-01-460 EXTRUDED RUBBER SEAL (1) with the Silicone Adhesive Sealant-General Purpose One part legacy (Material No.06CMD9) .
   (6) Make sure that the extruded rubber seal (1) is in the correct position.
   (7) Do an operational check to make sure that the door continues to open/close correctly.
5. Close-up
Subtask 52-11-18-942-057-A
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Obey the special precautions after the work on the door (Ref. AMM TASK 52-10-00-860-002).
   (3) Close the door 831 or 841 (Ref. AMM TASK 52-10-00-410-001).
   (4) Remove the access platform(s).
[Rev.10 from 2021] 2026.04.02 07:22:04 UTC