W DOC AIRBUS | AMM A320F

Operational Test of the Emergency Shutdown Circuit (using the APU Shut Off Switch 1KL) (APS 3200)


TASK 49-62-00-710-004-A
Operational Test of the Emergency Shutdown Circuit (using the APU Shut Off Switch 1KL) (APS 3200)


1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 31-60-00-860-001-A
EIS Start Procedure
TASK 31-60-00-860-002-A
EIS Stop Procedure
3. Job Set-up
Subtask 49-62-00-865-053-A ** ON A/C NOT FOR ALL
A. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
49VUAPU/FUEL/BLOW OFF/PUMP2QCB14
121VUAPU/FUEL/BLOW OFF/CTL1QCK39
121VUAPU/FIRE AND OVHT/DET/LOOP B2WGL44
121VUAPU/FIRE AND OVHT/DET/LOOP A1WGL43
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
121VUAPU/FIRE/EXTIG/SQUIB/B2WFL39
121VUAPU/FIRE/EXTIG/SQUIB/A1WFL38
121VUAPU/FIRE/LP VALVE/NORM4WFM42
121VUAPU/FIRE/LP VALVE/STBY3WFM41
121VUAPU/FUEL/LP VALVE/CTL1QFM40
121VUAPU/FUEL/LP VALVE/SPLY2QFM39
121VUAPU/FUEL/PUMP/CTL3QCM38
Subtask 49-62-00-860-052-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Do the EIS start procedure (upper ECAM DU and lower ECAM DU only)
(Ref. AMM TASK 31-60-00-860-001).
4. Procedure
Subtask 49-62-00-710-055-A ** ON A/C NOT FOR ALL
A. Operational Test of the Emergency Shutdown System
ACTION
RESULT
1.In the INT LT section of overhead panel 25VU:
  • Put the ANN LT switch in the TEST position.
In the cockpit:
  • All annunciator lights come on fully bright.
2.In the INT LT section of overhead panel 25VU:
  • Put the ANN LT switch in the BRT position.
In the cockpit:
  • The applicable annunciator lights go off.
3.On overhead panel 25VU:
  • Push the pushbutton APU MASTER SW to the ON position.
On overhead panel 25VU:
  • The ON legend in the pushbutton APU MASTER SW comes on.
4.On the ECAM control panel:
  • Push the FUEL pushbutton switch.
On the ECAM lower display unit:
  • The FUEL page comes into view.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in the open position.
5.On external power control-panel 108VU:
  • Push the APU SHUT OFF pushbutton switch (guarded red).
On the ECAM upper display unit:
  • The warning,
    APU EMER SHUT DOWN
    MASTER SW .... OFF
    comes on.

On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights come on,
  • A single chime is heard.

On overhead panel 25VU:
  • The FAULT legend in the pushbutton APU MASTER SW comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in the closed position.
6.On external power control-panel 108VU:
  • Release the APU SHUT OFF pushbutton switch and close the guard.

7.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The FAULT legend in the APU MASTER SW pushbutton switch goes off,
  • The ON legend in the APU MASTER SW pushbutton switch goes off.

On the ECAM upper display unit:
  • The warning,
    MASTER SW .... OFF
    goes off.
8.On glareshield panel 130VU or 131VU:
  • Push the MASTER CAUT pushbutton switch.
On glareshield panels 130VU and 131VU:
  • The MASTER CAUT lights go off.
9.On overhead panel 25VU:
  • Push and release the APU MASTER SW twice (on/off) to reset the ECB (59KD).
On the ECAM upper display unit:
  • The warning,
    APU EMER SHUT DOWN
    goes off.
10.On overhead panel 25VU:
  • push the APU MASTER SW to ON position.
On overhead panel 25VU:
  • The ON legend in the pushbutton APU MASTER SW comes on.

On the FUEL page of the ECAM lower display unit:
  • The APU LP fuel-valve symbol is shown in the open position.
11.On overhead panel 25VU:
  • Release the APU MASTER SW pushbutton switch.
On overhead panel 25VU:
  • The FAULT legend in the APU MASTER SW pushbutton switch goes off,
  • The ON legend in the APU MASTER SW pushbutton switch goes off.
5. Close-up
Subtask 49-62-00-860-053-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Do the EIS stop procedure
(Ref. AMM TASK 31-60-00-860-002).
   (2) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.01 01:31:53 UTC