Removal of the Start Contactors
TASK 49-42-55-000-001-A
Removal of the Start Contactors
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 49-42-55-010-050-A
Subtask 49-42-55-020-050-A
[Rev.10 from 2021]
2026.04.01 01:30:42 UTC
Removal of the Start Contactors
WARNING:
MAKE SURE THAT NO AC OR DC POWER IS CONNECTED TO THE AIRCRAFT ELECTRICAL CIRCUITS.
THERE IS A RISK OF ELECTROCUTION IF THE AC OR DC POWER STAYS CONNECTED.
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | AR | ACCESS PLATFORM 1M (3 FT)-ADJUSTABLE |
| No specific | AR | CAP - BLANKING |
| No specific | 1 | SOCKET DIA 13 MM (0,51 IN) |
| No specific | AR | WARNING NOTICE(S) |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 121AL |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 25-11-41-000-001-A | Removal of the Third Occupant Seat |
Subtask 49-42-55-010-050-A
A. Get Access
(1) Remove the third occupant seat (Ref. AMM TASK 25-11-41-000-001)
(2) In the cockpit, on the left lower side of the panel 120VU:
(4) Open the access door 121AL.
Subtask 49-42-55-860-050-A (1) Remove the third occupant seat (Ref. AMM TASK 25-11-41-000-001)
(2) In the cockpit, on the left lower side of the panel 120VU:
- open the access door (1).
(4) Open the access door 121AL.
B. Safety Precautions
(1) Make sure that the external power connector is not connected to the aircraft EXT PWR receptacle.
(2) Put a warning notice on the access door 121AL to tell persons not to connect the external power connector.
(3) In the cockpit, on the overhead panel 35VU, make sure these pushbutton switches are released:
4. Procedure(1) Make sure that the external power connector is not connected to the aircraft EXT PWR receptacle.
(2) Put a warning notice on the access door 121AL to tell persons not to connect the external power connector.
(3) In the cockpit, on the overhead panel 35VU, make sure these pushbutton switches are released:
- APU GEN,
- BAT 1, BAT 2,
- GEN 1, GEN 2,
- EXT PWR.
- 21VU (EMER ELEC PWR),
- 25VU (APU),
- 35VU (ELEC).
Subtask 49-42-55-020-050-A
A. Removal of the Start Contactor(s)
(1) Disconnect the electrical connector(s) (2).
(2) Put CAP - BLANKING on the disconnected electrical connector(s) (2).
(3) Use a SOCKET DIA 13 MM (0,51 IN) to loosen the captive screws (3) and remove the contactor(s) (4) from the DC Bus 1 Contactor Module (13PN).
(1) Disconnect the electrical connector(s) (2).
(2) Put CAP - BLANKING on the disconnected electrical connector(s) (2).
(3) Use a SOCKET DIA 13 MM (0,51 IN) to loosen the captive screws (3) and remove the contactor(s) (4) from the DC Bus 1 Contactor Module (13PN).
NOTE: Do not remove the captive screws (3) and the crinkle washers from the contactor(s) (4).
Start Contactors