W DOC AIRBUS | AMM A320F

Removal of the Starter Motor (APS 3200)


TASK 49-42-51-000-007-A
Removal of the Starter Motor (APS 3200)


WARNING: ISOLATE ALL THE AIRCRAFT ELECTRICAL CIRCUITS.
WARNING: DO NOT TOUCH THE APU UNTIL IT IS SUFFICIENTLY COOL TO PREVENT BURNS WHEN YOU DO THE MAINTENANCE TASK(S).
FIN: 8KA ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE
No specific
AR
CAP - BLANKING
No specific
AR
SAFETY CLIP - CIRCUIT BREAKER
No specific
AR
WARNING NOTICE(S)
98L12003001000
AR
HARNESS,SAFETY
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
315AL, 316AR
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-42-00-861-001-A
Energize the Ground Service Network from the External Power
TASK 29-00-00-864-001-A
Put the Related Hydraulic System in the Depressurized Configuration before Maintenance Action
TASK 52-41-00-010-001-A
Open the APU Doors for Access
3. Job Set-up
Subtask 49-42-51-860-087-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the ground service network
(Ref. AMM TASK 24-42-00-861-001).
   (2) On overhead panel 25VU, make sure that the APU MASTER SW pushbutton switch is released (the ON legend is off).
   (3) On the APU section of overhead panel 25VU, put the WARNING NOTICE(S) in position to tell persons not to start the APU.
   (4) Make sure that the hydraulic systems are depressurized
(Ref. AMM TASK 29-00-00-864-001).
Subtask 49-42-51-865-086-A ** ON A/C NOT FOR ALL
B. Open, safety and tag this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUAPU/APU/CTL2KDL42
121VUAPU/ECB/SPLY1KDL41
Subtask 49-42-51-010-074-A ** ON A/C NOT FOR ALL
C. Get Access
WARNING: BEFORE YOU START WORK, YOU MUST PUT ON A SAFETY HARNESS AND ATTACH IT TO THE ACCESS PLATFORM. WITHOUT A SAFETY HARNESS, YOU CAN FALL. THIS CAN KILL YOU OR CAUSE YOU INJURY.
   (1) Put on and attach the HARNESS, SAFETY before you start work in the work area.
   (2) Put the ACCESS PLATFORM 4M (13 FT)-ADJUSTABLE in position below APU access doors 315AL and 316AR.
   (3) Open APU access doors 315AL and 316AR (Ref. AMM TASK 52-41-00-010-001).
   (4) Set the light switch 11LJ to the ON position.
4. Procedure
Subtask 49-42-51-020-062-A ** ON A/C NOT FOR ALL
A. Removal of the Starter Motor
   (1) Disconnect the electrical connector P32 (1) from the starter motor (11).
   (2) Put the CAP-BLANKING on each disconnected electrical connector and receptacle.
   (3) Carefully pull back the rubber sleeves (6) to get access to the starter motor terminals.
CAUTION: MAKE MATCH MARKS ON ALL THE ELECTRICAL WIRES BEFORE YOU DISCONNECT THEM. INCORRECT CONNECTION OF WIRES WILL CAUSE DAMAGE TO EQUIPMENT.
   (4) Remove the nuts (5) and (7), the lock-washers (4),(8) together with the washers (2),(9) from the starter-motor terminals.
   (5) Disconnect the neg. lead (3) and the pos. lead (10) from the starter motor terminals.
   (6) Remove the washers (2), (9) from the bottom of the starter motor terminals.
   (7) Loosen the V-band clamp (14).
   (8) Remove the starter motor (11) and the packing (13) from the gearbox. Discard the packing (13).
[Rev.10 from 2021] 2026.04.01 01:30:30 UTC