Installation of the IGGS In-Tank Housing


TASK 47-20-41-400-001-A
Installation of the IGGS In-Tank Housing


WARNING: PUT THE SAFETY DEVICES AND THE WARNING NOTICES IN POSITION BEFORE YOU START A TASK ON OR NEAR:
  • THE FLIGHT CONTROLS
  • THE FLIGHT CONTROL SURFACES
  • THE LANDING GEAR AND THE RELATED DOORS
  • COMPONENTS THAT MOVE.
MOVEMENT OF COMPONENTS CAN KILL OR CAUSE INJURY TO PERSONS AND/OR CAN CAUSE DAMAGE TO THE EQUIPMENT.
WARNING: YOU MUST WEAR SAFETY BREATHING EQUIPMENT WHEN YOU DO WORK IN THIS AREA. THIS AREA CAN CONTAIN AIR FROM THE TANK INERTING SYSTEM. AIR FROM THIS SYSTEM HAS A LOW-OXYGEN CONTENT AND CAN CAUSE INJURY AND DEATH.
WARNING: MAKE SURE THAT:
  • THERE ARE NO CAPS OR COVERS ON THE FUEL TANK VENTILATION DUCTS. CAPS OR COVERS WILL CAUSE OVERPRESSURE OR UNDERPRESSURE DAMAGE TO THE FUEL TANK.
  • NO PERSONS ARE NEAR THE FUEL TANK OR VENTILATION DUCTS OF THE FUEL TANK.
ZONE: 141
FIN: 3YM ** ON A/C NOT FOR ALL
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE
No specific
AR
SAFETY BARRIER(S)
No specific
Torque wrench: range to between 0.80 and 0.70 m.daN (70.80 and 61.95 lbf.in ) T
 B. Consumable Materials
REFERENCE
DESIGNATION
(Material No.04TMB2)
Varnish-- Electrical Bonding Structure
 C. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
141
WING CENTER BOX
 D. Expendable Parts
FIG.ITEM
DESIGNATION
IPC-CSN
2
O-RING
AIPC 47-20-04-01-130
2
O-RING
AIPC 47-20-84-01-120
 E. Referenced Information
REFERENCE
DESIGNATION
TASK 12-11-28-650-003-A
Pressure Refuel with Automatic Control
TASK 20-21-12-911-001-A
Tightening Torques for Pipe Unions (not for OXYGEN Unions)
TASK 20-28-00-912-802-A
Electrical Bonding - General Maintenance Procedure
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 28-10-00-910-002-A
Access to the Fuel Tanks and the Work Areas
TASK 28-10-00-910-003-A
Safety Procedures When You Do Work in a Dry Fuel Tank
TASK 28-25-00-650-001-A
Pressure Defuel
TASK 28-25-00-650-003-A
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 28-25-00-650-003-A-01
To Drain Remaining Fuel from the Wing Tanks and the Center Tank
TASK 47-20-43-400-001-A
Installation of the Dual-Flapper Check Valve
TASK 47-31-34-740-001-A
BITE Test of the IGGS with Bleed Air
TASK 47-31-34-740-001-A-01
BITE Test of the IGGS without Bleed Air
3. Job Set-up
Subtask 47-20-41-941-051-A ** ON A/C NOT FOR ALL
A. Safety Precautions
WARNING: BEFORE YOU DO WORK IN OR NEAR A FUEL TANK, MAKE SURE THAT YOU OBEY ALL THE SAFETY PROCEDURES. THIS WILL PREVENT INJURY TO PERSONS AND/OR DAMAGE TO THE AIRCRAFT.
   (1) You must obey the fuel safety procedures when you do work in the fuel tank (Ref. AMM TASK 28-10-00-910-003).
   (2) Make sure that the SAFETY BARRIER(S) are in position.
Subtask 47-20-41-860-051-A ** ON A/C NOT FOR ALL
B. Aircraft Maintenance Configuration
   (1) Make sure that the aircraft electrical circuits are de-energized (Ref. AMM TASK 24-41-00-862-002).
Subtask 47-20-41-865-051-A ** ON A/C NOT FOR ALL
C. Make sure that this(these) circuit breaker(s) is(are) open, safetied and tagged:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUIGGS/CTRL7YAN28
** ON A/C NOT FOR ALL
121VUIGGS/CTRL7YAP28
** ON A/C NOT FOR ALL
122VUCSAS / CTRL1HWU17
Subtask 47-20-41-650-051-A ** ON A/C NOT FOR ALL
D. Fuel Configuration
   (1) Make sure that the center tank is defueled (Ref. AMM TASK 28-25-00-650-001) (Ref. AMM TASK 28-25-00-650-003).
Subtask 47-20-41-010-051-A ** ON A/C NOT FOR ALL
E. Get Access
   (1) Make sure that the ACCESS PLATFORM 2M (6 FT) - ADJUSTABLE is in position at the zone 142.
   (2) Get access to the center tank (Ref. AMM TASK 28-10-00-910-002).
4. Procedure
Subtask 47-20-41-420-050-A ** ON A/C NOT FOR ALL
CAUTION: BE CAREFUL WHEN YOU TOUCH THIS ASSEMBLY. IT HAS PRECISION- TOLERANCE COMPONENTS WITH VERY POLISHED SURFACES. IF YOU ARE NOT CAREFUL, IT IS VERY EASY TO CAUSE DAMAGE TO THESE COMPONENTS (INTERNAL CONTAMINATION, EXTERNAL IMPACT DAMAGE).
A. Installation of the IGGS In-Tank Housing
NOTE: Two persons are necessary to do this procedure. One person is in the center tank to hold the IGGS in-tank housing. The other person is on top of the center tank to install the attaching parts.
   (1) Install the new AIPC 47-20-04-01-130 O-RING (2) or AIPC 47-20-84-01-120 O-RING (2) on the IGGS in-tank housing (3).
   (2) Hold the IGGS in-tank housing (3) in position and install the nuts (1).
   (3) TORQUE the nuts (1) to between 0.80 and 0.70 m.daN (70.80 and 61.95 lbf.in )
T.
   (4) Remove the PLUG-BLANKING from each disconnected line end.
   (5) Install the union (6) on the IGGS in-tank housing (3) (
Ref. AMM TASK 20-21-12-911-001).
   (6) Install the bonding lead (5) with the screw (4) (Ref. AMM TASK 20-28-00-912-802).
   (7) Install the bonding lead (7) with the screw (8) (Ref. AMM TASK 20-28-00-912-802).
   (8) Apply Varnish-- Electrical Bonding Structure (Material No.04TMB2) on the screw heads (4) and (8).
   (9) Install the dual-flapper check valve (Ref. AMM TASK 47-20-43-400-001).
Subtask 47-20-41-865-052-A ** ON A/C NOT FOR ALL
B. Remove the safety clip(s) and the tag(s) and close this(these) circuit breaker(s):
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
121VUIGGS/CTRL7YAN28
** ON A/C NOT FOR ALL
121VUIGGS/CTRL7YAP28
** ON A/C NOT FOR ALL
122VUCSAS / CTRL1HWU17
Subtask 47-20-41-790-050-A ** ON A/C NOT FOR ALL
C. Leak Test
NOTE: You must do the two subsequent steps at the same time. Two persons are necessary to do these steps.
   (1) Do the BITE test of the Inert Gas Generation System (IGGS) with bleed air (Ref. AMM TASK 47-31-34-740-001).
   (2) Examine the joints on the in-tank housing (3) and the duct assembly (6) for air leakage.
NOTE: Air leaks are not permitted.
   (3) Do the double barrier check of the dual-flapper check valve (Ref. AMM TASK 47-20-43-400-001).
5. Close-up
Subtask 47-20-41-410-050-A ** ON A/C NOT FOR ALL
A. Close Access
   (1) Make sure that the work area is clean and clear of tools and other items.
   (2) Close the access panels (Ref. AMM TASK 28-10-00-910-002).
   (3) Remove the access platform.
Subtask 47-20-41-650-052-A ** ON A/C NOT FOR ALL
B. Fuel Configuration
   (1) Refuel the center tank (Ref. AMM TASK 12-11-28-650-003).
Subtask 47-20-41-860-053-A ** ON A/C NOT FOR ALL
C. Put the aircraft back to its initial configuration.
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Remove the ground support and maintenance equipment, the special and standard tools and all other items.