Software and Parameter Loading procedure from current Repository
TASK 46-41-00-970-807-A
Software and Parameter Loading procedure from current Repository
To load field-loadable software from the current repository.
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 46-41-00-861-060-D ** ON A/C NOT FOR ALL
Subtask 46-41-00-970-057-D ** ON A/C NOT FOR ALL
Subtask 46-41-00-862-060-D ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:26:12 UTC
Software and Parameter Loading procedure from current Repository
ZONE: 200
1. Reason for the JobTo load field-loadable software from the current repository.
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 46-41-00-610-811-A | Get access to the ALNA Graphical User Interface (GUI) - Maintenance Access - with Multi-Purpose Flight-Attendant Panel (MP-FAP) |
Subtask 46-41-00-861-060-D ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Access the ALNA Graphical User Interface (GUI) - Maintenance Access - via Multi-Purpose Flight-Attendant Panel (MP-FAP) (Ref. AMM TASK 46-41-00-610-811).
Subtask 46-41-00-865-062-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Access the ALNA Graphical User Interface (GUI) - Maintenance Access - via Multi-Purpose Flight-Attendant Panel (MP-FAP) (Ref. AMM TASK 46-41-00-610-811).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WAP | 27MH | D07 |
| 2000VU | CINS-HESU | 21RF | E02 |
Subtask 46-41-00-970-057-D ** ON A/C NOT FOR ALL
A. Software and parameter uploading procedure from the current repository.
5. Close-up| ACTION | RESULT |
|---|---|
| In the cabin, at the MP-FAP: | In the cabin, on the MP-FAP display: |
| 1.Touch the "DATA LOADING" icon. |
|
NOTE: If there is no selection of a software or parameter package and the icon "INSTALL" is deactivated, do nothing. | |
| 2.Touch the "INSTALL" icon. |
|
| 3.Touch the "OK" icon to start the installation. |
|
| |
|
| 4.Touch the "OK" icon. | |
| 5.Touch the "SYSTEM MON." icon. |
|
| 6.Touch the "RESET" icon in the HESU line to start the HESU again. | |
| 7.Wait for approximately 15 minutes. |
|
Subtask 46-41-00-862-060-D ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(2) Touch the "LOGOFF" icon.
(Ref. AMM TASK 24-41-00-862-002).
(1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(2) Touch the "LOGOFF" icon.
NOTE: It is not necessary to log off, if you continue with a different test procedure.
(3) De-energize the aircraft electrical circuits(Ref. AMM TASK 24-41-00-862-002).