W DOC AIRBUS | AMM A320F

Download Engineering Data to the USB flash drive with the Multi-Purpose Flight-Attendant Panel (MP-FAP)


TASK 46-41-00-720-819-A
Download Engineering Data to the USB flash drive with the Multi-Purpose Flight-Attendant Panel (MP-FAP)


ZONE: 200
1. Reason for the Job
Self explanatory
2. Job Set-up Information
 A. Fixtures, Tools, Test and Support Equipment
REFERENCE
QTY
DESIGNATION
No specific
1
USB FLASH DRIVE, MIN. 2GB CAPACITY
 B. Work Zones and Access Panels
ZONE/ACCESS
ZONE DESCRIPTION
200
UPPER HALF FUSELAGE
 C. Referenced Information
REFERENCE
DESIGNATION
TASK 24-41-00-861-002-A
Energize the Aircraft Electrical Circuits from the External Power
TASK 24-41-00-861-002-A-01
Energize the Aircraft Electrical Circuits from the APU
TASK 24-41-00-861-002-A-02
Energize the Aircraft Electrical Circuits from Engine 1(2)
TASK 24-41-00-862-002-A
De-energize the Aircraft Electrical Circuits Supplied from the External Power
TASK 24-41-00-862-002-A-01
De-energize the Aircraft Electrical Circuits Supplied from the APU
TASK 24-41-00-862-002-A-02
De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2)
TASK 46-41-00-610-811-A
Get access to the ALNA Graphical User Interface (GUI) - Maintenance Access - with Multi-Purpose Flight-Attendant Panel (MP-FAP)
3. Job Set-up
Subtask 46-41-00-861-142-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
   (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
   (2) Access the ALNA Graphical User Interface (GUI) - Maintenance Access - via Multi-Purpose Flight-Attendant Panel (MP-FAP) (Ref. AMM TASK 46-41-00-610-811).
Subtask 46-41-00-865-170-A ** ON A/C NOT FOR ALL
B. Make sure that this(these) circuit breaker(s) is(are) closed:
PANELDESIGNATIONFINLOCATION
** ON A/C NOT FOR ALL
2000VUWAP27MHD07
2000VUCINS-HESU21RFE02
4. Procedure
Subtask 46-41-00-720-069-A ** ON A/C NOT FOR ALL
A. Download the Engineering Data to the USB flash drive with the Multi-Purpose Flight-Attendant Panel (MP-FAP)
NOTE: It is recommended to use a high speed USB flash drive 2.0 with a minimum capacity of 2GB.
ACTION
RESULT
In the cabin, at the MP-FAP:
In the cabin, on the MP-FAP display:
1.Touch the "MISCELLANEOUS" icon.
  • The "MISCELLANEOUS" page shows.
2.Put the USB FLASH DRIVE, MIN. 2GB CAPACITY into the USB port of the MP-FAP and wait one minute.

3.Touch the "EXPORT" icon.
  • The message "EXPORT OF ENGINEERING DATA WILL TAKE TYPICALLY 10 MINUTES WITH USB 2.0 DEVICE. CONTINUE?" shows.
4.Touch the "OK" icon and wait until the export is completed.
  • The message "LOG-FILE EXPORT TO USB_STICK CONNECTED TO FAP-ML IS IN PROGRESS" shows.
5.Remove the USB flash drive.

5. Close-up
Subtask 46-41-00-862-141-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
   (1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
   (2) Touch the "LOGOFF" icon.
NOTE: It is not necessary to log off, if you continue with a different test procedure.
   (3) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
[Rev.10 from 2021] 2026.04.02 06:26:13 UTC