Operational Test of the Cellular Gatelink
TASK 46-41-00-710-812-A
Operational Test of the Cellular Gatelink
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
B. Work Zones and Access Panels
C. Referenced Information
3. Job Set-up
Subtask 46-41-00-860-089-A ** ON A/C NOT FOR ALL
Subtask 46-41-00-710-064-A ** ON A/C NOT FOR ALL
Subtask 46-41-00-860-090-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:26:14 UTC
Operational Test of the Cellular Gatelink
1. Reason for the Job
Self explanatory
2. Job Set-up Information
A. Fixtures, Tools, Test and Support Equipment
| REFERENCE | QTY | DESIGNATION |
|---|---|---|
| No specific | 1 | ACCESS PLATFORM 2M (6 FT) |
| No specific | AR | LAPTOP - FOR GSM ALNA MAINTENANCE |
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 120 | AVIONICS COMPARTMENT |
| 220 | FWD CAB UTILITY AREAS |
| 824 |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 46-41-00-610-811-A | Get access to the ALNA Graphical User Interface (GUI) - Maintenance Access - with Multi-Purpose Flight-Attendant Panel (MP-FAP) |
| TASK 52-41-00-010-002-A | Open the Avionics Compartment Doors for Access |
| TASK 52-41-00-410-002-A | Close the Avionics Compartment Doors after Access |
| TASK 46-41-00-00 | CABIN INFORMATION NETWORK SYSTEM - DESCRIPTION AND OPERATION |
Subtask 46-41-00-860-089-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Access the ALNA Graphical User Interface - Maintenance Access - via Multi-Purpose Flight-Attendant Panel (MP-FAP) (Ref. AMM TASK 46-41-00-610-811).
Subtask 46-41-00-865-171-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Access the ALNA Graphical User Interface - Maintenance Access - via Multi-Purpose Flight-Attendant Panel (MP-FAP) (Ref. AMM TASK 46-41-00-610-811).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
Subtask 46-41-00-860-091-A ** ON A/C NOT FOR ALL | PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | CINS-HESU | 21RF | E02 |
C. Preparation for the Test
(1) Get access to the Head End Server Unit (HESU) as follows:
(a) For the location of this component, refer to paragraph Component Location
(Ref. AMM D/O 46-41-00-00).
(b) Put an ACCESS PLATFORM 2M (6 FT) in position at access door 824.
(c) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
(2) Make sure that the SIM card is installed in HESU as follows:
(a) Loosen the applicable screw and open the HESU flap.
(b) Make sure that the SIM card is installed in the SIM card slot.
(c) Close the HESU flap and hand tighten the applicable screw.
4. Procedure(1) Get access to the Head End Server Unit (HESU) as follows:
(a) For the location of this component, refer to paragraph Component Location
(Ref. AMM D/O 46-41-00-00).
(b) Put an ACCESS PLATFORM 2M (6 FT) in position at access door 824.
(c) Open access door 824 (Ref. AMM TASK 52-41-00-010-002).
(2) Make sure that the SIM card is installed in HESU as follows:
(a) Loosen the applicable screw and open the HESU flap.
(b) Make sure that the SIM card is installed in the SIM card slot.
(c) Close the HESU flap and hand tighten the applicable screw.
Subtask 46-41-00-710-064-A ** ON A/C NOT FOR ALL
A. Operational Test of the Cellular Gatelink
5. Close-upNOTE: You can do this procedure at the MP-FAP or on the LAPTOP - FOR GSM ALNA MAINTENANCE. The procedures at the MP-FAP and on the maintenance laptop are the same.
NOTE: The table that follows gives the procedure for the MP-FAP.
| ACTION | RESULT |
|---|---|
| In the cabin, at the MP-FAP: | In the cabin, on the MP-FAP display: |
| 1.Touch the "SYSTEM MONITORING" icon. |
|
| 2.Select the "OVERVIEW" tab. | |
| |
| 3.Touch the "SYSTEM TEST" icon. |
|
| 4.Select the "CALIBRATION & FUNCTION TEST" tab. |
|
|
|
|
|
|
|
|
|
|
|
|
|
| |
| 5.Touch the "MISCELLANEOUS" icon. |
|
| 6.Select the "CELLULAR GATELINK" tab. |
|
| |
| 7.Touch the "CLOSE" icon. |
|
Subtask 46-41-00-860-090-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Touch the "LOGOFF" icon.
(5) Remove the access platform(s).
(6) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).
(1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(2) Make sure that the work area is clean and clear of tools and other items.
(3) Touch the "LOGOFF" icon.
NOTE: It is not necessary to log off, if you continue with a different test procedure.
(4) Close access door 824 (Ref. AMM TASK 52-41-00-410-002).(5) Remove the access platform(s).
(6) De-energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-862-002).