ALNA Internal Wiring Test
TASK 46-41-00-700-803-A
ALNA Internal Wiring Test
Self explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
B. Referenced Information
3. Job Set-up
Subtask 46-41-00-861-153-A ** ON A/C NOT FOR ALL
Subtask 46-41-00-710-063-A ** ON A/C NOT FOR ALL
Subtask 46-41-00-862-152-A ** ON A/C NOT FOR ALL
[Rev.10 from 2021]
2026.04.02 06:26:15 UTC
ALNA Internal Wiring Test
ZONE: 200
1. Reason for the JobSelf explanatory
2. Job Set-up Information
A. Work Zones and Access Panels
| ZONE/ACCESS | ZONE DESCRIPTION |
|---|---|
| 200 | UPPER HALF FUSELAGE |
| REFERENCE | DESIGNATION |
|---|---|
| TASK 24-41-00-861-002-A | Energize the Aircraft Electrical Circuits from the External Power |
| TASK 24-41-00-861-002-A-01 | Energize the Aircraft Electrical Circuits from the APU |
| TASK 24-41-00-861-002-A-02 | Energize the Aircraft Electrical Circuits from Engine 1(2) |
| TASK 24-41-00-862-002-A | De-energize the Aircraft Electrical Circuits Supplied from the External Power |
| TASK 24-41-00-862-002-A-01 | De-energize the Aircraft Electrical Circuits Supplied from the APU |
| TASK 24-41-00-862-002-A-02 | De-energize the Aircraft Electrical Circuits Supplied from the Engine 1(2) |
| TASK 46-41-00-610-811-A | Get access to the ALNA Graphical User Interface (GUI) - Maintenance Access - with Multi-Purpose Flight-Attendant Panel (MP-FAP) |
Subtask 46-41-00-861-153-A ** ON A/C NOT FOR ALL
A. Aircraft Maintenance Configuration
(1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Access the ALNA Graphical User Interface (GUI) - Maintenance Access - via Multi-Purpose Flight-Attendant Panel (MP-FAP) (Ref. AMM TASK 46-41-00-610-811).
Subtask 46-41-00-865-164-A ** ON A/C NOT FOR ALL (1) Energize the aircraft electrical circuits
(Ref. AMM TASK 24-41-00-861-002).
(2) Access the ALNA Graphical User Interface (GUI) - Maintenance Access - via Multi-Purpose Flight-Attendant Panel (MP-FAP) (Ref. AMM TASK 46-41-00-610-811).
B. Make sure that this(these) circuit breaker(s) is(are) closed:
4. Procedure| PANEL | DESIGNATION | FIN | LOCATION |
|---|---|---|---|
| ** ON A/C NOT FOR ALL | |||
| 2000VU | WAP | 27MH | D07 |
| 2000VU | CINS-HESU | 21RF | E02 |
Subtask 46-41-00-710-063-A ** ON A/C NOT FOR ALL
A. ALNA Internal Wiring Test
5. Close-up| ACTION | RESULT |
|---|---|
| In the cabin, at the MP-FAP: | In the cabin, on the MP-FAP display: |
| 1.Touch the "SYSTEM TEST" icon. |
|
| 2.Select the "CONNECTIVITY INTERNAL WIRING" tab. |
|
| 3.Touch the "ALNA INTERNAL WIRING TEST" icon. |
|
| 4.Touch the "START TEST" icon. |
|
| 5.Touch the "START" icon. |
|
| 6.Wait until the test is completed and the "TEST RESULT" icon becomes active. |
|
| 7.Touch the "TEST RESULTS" icon. |
|
| 8.Use the "ARROW DOWN" icon right next to the table to scroll down the results. |
|
| 9.Touch the "NEXT" icon. |
|
| 10.Touch the "CLOSE" icon. |
|
Subtask 46-41-00-862-152-A ** ON A/C NOT FOR ALL
A. Put the aircraft back to its initial configuration.
(1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(2) Touch the "LOGOFF" icon.
(Ref. AMM TASK 24-41-00-862-002).
(1) Remove the ground support and maintenance equipment, the special and standard tools and all other items.
(2) Touch the "LOGOFF" icon.
NOTE: It is not necessary to log off, if you continue with a different test procedure.
(3) De-energize the aircraft electrical circuits(Ref. AMM TASK 24-41-00-862-002).